78M6612 Data Sheet  
DS_6612_001  
must be 12 (allowing for one settling cycle). The required configuration is FIR_LEN = 1 (three cycles per  
conversion) and MUX_DIV[1:0] = 01 (4 conversions per mux frame).  
During operation, the MPU is in charge of controlling the multiplexer cycles, for example by inserting an  
alternate multiplexer sequence at regular intervals using MUX_ALT. This enables temperature  
measurement. The polarity of chopping circuitry must be altered for each sample. It must also alternate  
for each alternate multiplexer reading. This is accomplished by maintaining CHOP_E = 00.  
4.4.5 CE Calculations  
The CE performs the precision computations necessary to accurately measure energy. These  
computations include offset cancellation, products, product smoothing, product summation, frequency  
detection, VAR calculation, sag detection, peak detection, and voltage phase measurement. Refer to the  
applicable 78M6612 Firmware Description Document.  
4.4.6 CE Status  
Since the CE_BUSY interrupt occurs at 2520.6 Hz, it is desirable to minimize the computation required  
in the interrupt handler of the MPU. The MPU can read the CE status word at every CE_BUSY interrupt.  
CE  
Address  
Name  
CESTATUS  
Description  
0x70  
See description of CE status word below.  
The CE Status Word is used for generating early warnings to the MPU. It contains sag warnings for VA  
as well as F0, the derived clock operating at the fundamental input frequency. CESTATUS provides  
information about the status of voltage and input AC signal frequency, which are useful for generating  
early power fail warnings, e.g. to initiate necessary data storage. CESTATUS represents the status flags  
for the preceding CE code pass (CE busy interrupt). Sag alarms are not remembered from one code  
pass to the next. The CE Status word is refreshed at every CE_BUSY interrupt.  
The significance of the bits in CESTATUS is shown in the table below:  
CESTATUS  
Name  
Description  
[bit]  
31-29  
28  
Not Used  
F0  
These unused bits will always be zero.  
F0 is a square wave at the exact fundamental input frequency.  
27  
Reserved  
Normally zero. Becomes one when VB remains below SAG_THR for  
SAG_CNT samples. Will not return to zero until VB rises above SAG_THR.  
26  
SAG_B  
Normally zero. Becomes one when VA remains below SAG_THR for  
SAG_CNT samples. Will not return to zero until VA rises above SAG_THR.  
25  
SAG_A  
24-0  
Not Used  
These unused bits will always be zero.  
84  
Rev. 1.2