 浏览型号78M6613-IM/F/PSP的Datasheet PDF文件第7页浏览型号78M6613-IM/F/PSP的Datasheet PDF文件第8页浏览型号78M6613-IM/F/PSP的Datasheet PDF文件第9页浏览型号78M6613-IM/F/PSP的Datasheet PDF文件第10页浏览型号78M6613-IM/F/PSP的Datasheet PDF文件第12页浏览型号78M6613-IM/F/PSP的Datasheet PDF文件第13页浏览型号78M6613-IM/F/PSP的Datasheet PDF文件第14页浏览型号78M6613-IM/F/PSP的Datasheet PDF文件第15页  
DS_6613_018  
78M6613 Data Sheet  
2 Functional Description  
2.1 Theory of Operation  
The energy delivered by a power source into a load can be expressed as:  
t
E = V (t)I(t)dt  
0
The following formulae apply for wide band mode (true RMS):  
P = (i(t) * v(t))  
Q = √(S2 – P2)  
S = V * I  
V = √∑v(t)2  
I = √∑i(t)2  
For a practical measurement, not only voltage and current amplitudes, but also phase angles and  
harmonic content may change constantly. Thus, simple RMS measurements are inherently inaccurate,  
and true RMS measurements must be utilized. A modern solid-state electricity Power and Energy  
Measurement IC such as the Teridian 78M6613 functions by emulating the integral operation above, i.e. it  
processes current and voltage samples through an ADC at a constant frequency. As long as the ADC  
resolution is high enough and the sample frequency is beyond the harmonic range of interest, the current  
and voltage samples, multiplied with the time period of sampling will yield an accurate quantity for the  
momentary energy. Summing up the momentary energy quantities over time will result in accumulated  
energy.  
500  
400  
300  
200  
100  
0
0
5
10  
15  
20  
-100  
-200  
-300  
-400  
-500  
Current [A]  
Voltage [V]  
Energy per Interval [Ws]  
Accumulated Energy [Ws]  
Figure 4: Voltage. Current, Momentary and Accumulated Energy  
Figure 4 shows the shapes of V(t), I(t), the momentary power and the accumulated power, resulting from  
50 samples of the voltage and current signals over a period of 20 ms. The application of 240 VAC and  
100 A results in an accumulation of 480 Ws (= 0.133 Wh) over the 20 ms period, as indicated by the  
Accumulated Power curve. The described sampling method works reliably, even in the presence of  
dynamic phase shift and harmonic distortion.  
For actual measurement equations, refer to the applicable firmware documentation.  
Rev. 1.1  
11