73S1217F Data Sheet
DS_1217F_002
Firmware sets
VCCSEL to 00
t5
t5 delay or
Card Event
IO
RST
CLK
CMDVCCnB
VCC
t3
t1
t2
t4
t1: Time after either a “card event” occurs or firmware sets the VCCSela and VCCSelb bits to 0 (see
t5, VCCOff_tmr) occurs until RST is asserted low.
t2: Time after RST goes low until CLK stops.
t3: Time after CLK stops until IO goes low.
t4: Time after IO goes low until VCC is powered down.
t5: Delayed VCC off time (in ETUs per VCCOff_tmr bits). Only in effect due to firmware
deactivation.
Figure 19: Deactivation Sequence
1.7.17.3
Data Reception/Transmission
When a 12Mhz crystal is used, the smart card UART will generate a 3.69Mhz (default) clock to both
smart card interfaces. This will allow approximately 9600bps (1/ETU) communication during ATR (ISO
7816 default). As part of the PPS negotiation between the smart card and the reader, the firmware may
determine that the smart card parameters F and D may be changed. After this negotiation, the firmware
may change the ETU by writing to the SFR FDReg to adjust the ETU and CLK. The firmware may also
change the smart card clock frequency by writing to the SFR SCCLK (SCECLK for external interface).
Independent clock frequency control is provided to each smart card interface. Clock stop high or Clock
stop low is supported in asynchronous mode. Figure 20 shows the ETU and CLK control circuits. The
firmware determines when clock stop is supported by the smart card and when it is appropriate to go into
that mode (and when to come out of it). The smart card UART is clocked by the same clock is provided
to the selected smart card. The transition between smart card clocks is handled in hardware to eliminate
any glitches for the UART during switchover. The external smart card clock is not affected when
switching the UART to communicate with the internal smart card.