 浏览型号73S1209F-68IMR/F的Datasheet PDF文件第72页浏览型号73S1209F-68IMR/F的Datasheet PDF文件第73页浏览型号73S1209F-68IMR/F的Datasheet PDF文件第74页浏览型号73S1209F-68IMR/F的Datasheet PDF文件第75页浏览型号73S1209F-68IMR/F的Datasheet PDF文件第77页浏览型号73S1209F-68IMR/F的Datasheet PDF文件第78页浏览型号73S1209F-68IMR/F的Datasheet PDF文件第79页浏览型号73S1209F-68IMR/F的Datasheet PDF文件第80页  
73S1209F Data Sheet  
DS_1209F_004  
VCCSEL  
bits  
VCC  
VCCOK  
RSTCRD  
RST  
t3  
CLK  
IO  
t4  
t1  
t2  
tto  
t1: The time from setting VCCSEL bits until VCCOK = 1.  
tto: The time from setting VCCSEL bits until VCCTMR times out. At t1 (if RDYST = 1) or tto (if RDYST = 0),  
activation starts. It is suggested to have RDYST = 0 and use the VCCTMR interrupt to let MPU know when  
sequence is starting.  
t2: time from start of activation (no external indication) until IO goes into reception mode (= 1). This is  
approximately 4 SCCLK (or SCECLK) clock cycles.  
t3: minimum one half of ETU period.  
t4: ETU period.  
Note that in Sync mode, IO as input is sampled on the rising edge of CLK. IO changes on the falling edge of CLK,  
either from the card or from the 73S1209F. The RST signal to the card is directly controlled by the RSTCRD bit  
(non-inverted) via the MPU and is shown as an example of a possible RST pattern.  
Figure 19: Synchronous Activation  
IO reception on  
5
2
RST  
CLK  
1
CLKOFF  
CLKLVL  
RLength Count  
RLenght = 1  
7
Count MAX  
3
4
Rlength Interrupt  
6
TX/RXB Mode bit  
(TX = '1')  
t1  
t1. CLK wll start at least 1/2 ETU after CLKOFF is set low  
when CLKLVL = 0  
1. Clear CLKOFF after Card is in reception mode.  
2. Set RST bit.  
3. Interrupt is generated when Rlength counter is MAX.  
4. Read and clear Interrupt.  
5. Clear RST bit.  
6. Toggle TX/RXB to reset bit counter.  
7. Reload RLength Counter.  
Figure 20: Example of Sync Mode Operation: Generating/Reading ATR Signals  
76  