 浏览型号73S1209F-68IM/F的Datasheet PDF文件第76页浏览型号73S1209F-68IM/F的Datasheet PDF文件第77页浏览型号73S1209F-68IM/F的Datasheet PDF文件第78页浏览型号73S1209F-68IM/F的Datasheet PDF文件第79页浏览型号73S1209F-68IM/F的Datasheet PDF文件第81页浏览型号73S1209F-68IM/F的Datasheet PDF文件第82页浏览型号73S1209F-68IM/F的Datasheet PDF文件第83页浏览型号73S1209F-68IM/F的Datasheet PDF文件第84页  
73S1209F Data Sheet  
DS_1209F_004  
Smart Card Interrupt Register (SCInt): 0xFE01 Å 0x00  
When the smart card interrupt is asserted, the firmware can read this register to determine the actual  
cause of the interrupt. The bits are cleared when this register is read. Each interrupt can be disabled by  
the Smart Card Interrupt Enable register. Error processing must be handled by the firmware. This  
register relates to the interface that is active – see the SCSel register (above).  
Table 74: The SCInt Register  
MSB  
LSB  
TXEVT TXSENT TXERR RXERR  
WAITTO CRDEVT VCCTMRI RXDAV  
Bit  
Symbol  
Function  
Wait Timeout – An ATR or card wait timeout has occurred. In sync mode,  
this interrupt is asserted when the RLen counter (it advances on falling  
edges of CLK/ETU) reaches the loaded (max) value. This bit is cleared  
when the SCInt register is read. When running in Synchronous Clock Stop  
Mode, this bit becomes RLenINT interrupt (set when the Rlen counter  
reaches the terminal count).  
SCInt.7  
WAITTO  
Card Event – A card event is signaled via pin DETCARD either when the  
Card was inserted or removed (read the CRDCtl register to determine card  
SCInt.6  
SCInt.5  
CRDEVT presence) or there was a fault condition in the interface circuitry. This bit is  
functional even if the smart card logic clock is disabled and when the  
PWRDN bit is set. This bit is cleared when the SCInt register is read.  
VCC Timer – This bit is set when the VCCTMR times out. This bit is cleared  
VCCTMRI  
when the SCInt register is read.  
Rx Data Available – Data was received from the smart card because the Rx  
FIFO is not empty. In bypass mode, this interrupt is generated on a falling  
edge of the smart card I/O line. After receiving this interrupt in bypass  
mode, firmware should disable it until the firmware has received the entire  
SCInt.4  
RXDAV  
byte and is waiting for the next start delimiter. This bit is cleared when there  
is no RX data available in the RX FIFO.  
TX Event – Set whenever the TXEMTY or TXFULL bits are set in the  
TXEVNT  
SCInt.3  
SCInt.2  
SRXCtl SFR. This bit is cleared when the STXCtl register is read.  
TX Sent – Set whenever the ISO UART has successfully transmitted a byte  
to the smart card. Also set when a CRC/LRC byte is sent in T=1 mode. Will  
not be set in T=0 when a break is detected at the end of a byte (when break  
TXSENT  
detection is enabled). This bit is cleared when the SCInt register is read.  
TX Error – An error was detected during the transmission of data to the  
smart card as indicated by either BREAKD or TXUNDR bit being set in the  
TXERR  
SCInt.1  
SCInt.0  
STXCtl SFR. Additional information can be found in that register  
description. This bit is cleared when the STXCtl register is read.  
RX Error – An error was detected during the reception of data from the  
smart card. Additional information can be found in the SRXCtl register. This  
RXERR  
interrupt will be asserted for RXOVRR, or RX Parity error events. This bit is  
cleared when the SRXCtl register is read.  
80  