 浏览型号73S1209F-68IM/F的Datasheet PDF文件第62页浏览型号73S1209F-68IM/F的Datasheet PDF文件第63页浏览型号73S1209F-68IM/F的Datasheet PDF文件第64页浏览型号73S1209F-68IM/F的Datasheet PDF文件第65页浏览型号73S1209F-68IM/F的Datasheet PDF文件第67页浏览型号73S1209F-68IM/F的Datasheet PDF文件第68页浏览型号73S1209F-68IM/F的Datasheet PDF文件第69页浏览型号73S1209F-68IM/F的Datasheet PDF文件第70页  
73S1209F Data Sheet  
DS_1209F_004  
Keypad Scan Time Register (KSIZE): 0xD5 Å 0x00  
This register is not applicable when HWSCEN is not set. Unused row inputs should be connected to  
VDD.  
Table 69: The KSIZE Register  
MSB  
LSB  
ROWSIZ.2 ROWSIZ.1 ROWSIZ.0 COLSIZ.2 COLSIZ.1 COLSIZ.0  
Bit  
Symbol  
Function  
KSIZE.7  
KSIZE.6  
KSIZE.5  
KSIZE.4  
KSIZE.3  
KSIZE.2  
KSIZE.1  
KSIZE.0  
ROWSIZ.2  
Defines the number of rows in the keypad. Maximum number is 6 given  
ROWSIZ.1 the number of row pins on the package. Allows for a reduced keypad size  
for scanning.  
ROWSIZ.0  
COLSIZ.2  
Defines the number of columns in the keypad. Maximum number is 5  
COLSIZ.1 given the number of column pins on the package. Allows for a reduced  
keypad size for scanning.  
COLSIZ.0  
Keypad Column LS Scan Order Register (KORDERL): 0xD6 Å 0x00  
In registers KORDERL and KORDERH, Column Scan Order(14:0) is grouped into 5 sets of 3 bits each.  
Each set determines which column (COL(4:0) pin) to activate by loading the column number into the 3  
bits. When in HW_Scan_Enable mode, the hardware will step through the sets from 1Col to 5Col (up to  
the number of columns in Colsize) and scan the column defined in the 3 bits. To scan in sequential  
order, set a counting pattern with 0 in set 0, and 1 in set 1,and 2 in set 2, and 3 in set 3, and 4 in set 4.  
The firmware should update this as part of the interrupt service routine so that the new scan order is  
loaded prior to the next key being pressed. For example, to scan COL(0) first, 1Col(2:0) should be  
loaded with 000’b. To scan COL(4) fifth, 5Col(2:0) should be loaded with 100’b.  
Table 70: The KORDERL Register  
MSB  
LSB  
3COL.1 3COL.0 2COL.2 2COL.1 2COL.0 1COL.2 1COL.1 1COL.0  
Bit  
Symbol  
3COL.1  
3COL.0  
2COL.2  
2COL.1  
2COL.0  
1COL.2  
1COL.1  
1COL.0  
Function  
KORDERL.7  
KORDERL.6  
KORDERL.5  
KORDERL.4  
KORDERL.3  
KORDERL.2  
KORDERL.1  
KORDERL.0  
Column to scan 3rd (lsb’s).  
Column to scan 2nd.  
Column to scan 1st.  
66  
Rev. 1.2  
 