FDS 6531/6532 005  
Data Sheet 71M6531D/F-71M6532D/F  
Error Band (PPM) over Temperature (°C)  
2800  
2400  
2000  
1600  
1200  
800  
±40 PPM/°C  
400  
0
-400  
-800  
-1200  
-1600  
-2000  
-2400  
-2800  
±40 PPM/°C  
-40  
-20  
0
20  
40  
60  
80  
Figure 31: Error Band for VREF over Temperature  
3.4.2 Temperature Compensation for VREF  
The bandgap temperature is used to digitally compensate the power outputs for the temperature dependence  
of VREF, using the CE register GAIN_ADJ. Since the band gap amplifier is chopper-stabilized, the most  
significant long-term drift mechanism in the voltage reference is removed.  
The following formula is used to determine the GAIN_ADJ value of the CE. In this formula, TEMP_X is the  
deviation from nominal or calibration temperature expressed in multiples of 0.1 °C:  
TEMP _ X PPMC TEMP _ X 2 PPMC2  
GAIN _ ADJ =16385+  
+
214  
223  
3.4.3 System Temperature Compensation  
In a production electricity meter, the 71M6531 or 71M6532D/F is not the only component contributing to  
temperature dependency. A whole range of components (e.g. current transformers, resistor dividers,  
power sources, filter capacitors) will contribute temperature effects.  
Since the output of the on-chip temperature sensor is accessible to the MPU, temperature compensation  
mechanisms with great flexibility are possible. MPU access to GAIN_ADJ permits a system-wide temperature  
correction over the entire meter rather than local to the chip.  
3.4.4 Temperature Compensation for the RTC  
In order to obtain accurate readings from the RTC, the following procedure is recommended:  
1. At the time of meter calibration, the crystal oscillator is calibrated using the RTCA_ADJ register in I/O  
RAM to be as close to 32768 Hz as possible. The recommended procedure is to connect a high-  
precision frequency counter to the TMUXOUT pin and select 0x11 for TMUX[4:0]. This will generate  
a 4-second pulse at TMUXOUT that can be used to trim RTCA_ADJ to the best value.  
2. When the meter is in service, the MPU takes frequent temperature readings. If the temperature  
characteristics of the crystal are known, the temperature readings can be used to modify the settings  
for the I/O RAM registers PREG[16:0] and QREG[1:0] in order to keep the crystal frequency close to  
32768 Hz.  
3. After periods of operation under battery power, the temperature for the time the meter was not powered  
can be estimated by averaging the temperatures before and after battery operation. Based on this, the  
overall correction for the RTC time can be calculated and applied to the RTC after main power returns  
to the meter.  
v1.3  
© 2005-2010 TERIDIAN Semiconductor Corporation  
65  
 
 
 
 