Data Sheet 71M6531D/F-71M6532D/F  
FDS 6531/6532 005  
In the absence of system power, if the voltage margin for the LDO regulator providing 2.5 V to the internal  
circuitry becomes too low to be safe, the part automatically enters sleep mode (BAT_OK false). The bat-  
tery voltage must stay above 3 V to ensure that BAT_OK remains true. Under this condition, the  
71M6531 stays in SLEEP mode, even if the voltage margin for the LDO improves (BAT_OK true). Table  
47 shows the circuit functions available in each operating mode.  
Table 47: Available Circuit Functions  
System Power  
MISSION  
Yes  
Battery Power (Nonvolatile Supply)  
Circuit Function  
BROWNOUT  
LCD  
SLEEP  
CE  
CE Data RAM  
FIR  
Yes  
Yes  
Yes  
Analog circuits  
MPU clock rate  
Yes  
From PLL, as  
defined by  
MPU_DIV  
28.672 kHz  
(7/8 of 32768 Hz)  
MPU_DIV  
ICE  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
DIO Pins  
Watchdog Timer  
LCD  
Yes  
Yes  
Yes  
Yes  
EEPROM Interface (2-wire)  
Yes (8 kb/s)  
EEPROM Interface (3-wire)  
UART  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes (16 kb/s)  
300 bd  
Optical TX modulation  
Flash Read  
Yes  
Yes  
Flash Page Erase  
Flash Write  
RAM Read and Write  
Yes  
Wakeup Timer  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
OSC and RTC  
XRAM data preservation  
Yes  
V3P3D voltage output pin  
GPO – GP7 registers  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
-- indicates not active  
2.3.1 BROWNOUT Mode  
In BROWNOUT mode, most non-metering digital functions are active (as shown in Table 47), including  
ICE, UART, EEPROM, LCD and RTC. In BROWNOUT mode, a low bias current regulator will provide  
2.5 Volts to V2P5 and V2P5NV. The regulator has an output called BAT_OK to indicate that it has suffi-  
cient overhead. When BAT_OK = 0, the part will enter SLEEP mode. From BROWNOUT mode, the pro-  
cessor can voluntarily enter LCD or SLEEP modes. When system power is restored, the part will auto-  
matically transition from any of the battery modes to MISSION mode, once the PLL has settled.  