Data Sheet 71M6531D/F-71M6532D/F  
FDS 6531/6532 005  
2.2  
System Timing Summary  
Figure 19 summarizes the timing relationships between the input MUX states, the CE_BUSY signal and  
the two serial output streams. In this example, MUX_DIV=4 and FIR_LEN=2 (384 CE cycles, 3 CK32  
cycles per conversion), resulting in 13 CK32 cycles per multiplexer frame. Generally, the duration of each  
MUX frame is:  
1 + MUX_DIV * 1, if FIR_LEN=0 (138 CE cycles)  
1 + MUX_DIV * 2, if FIR_LEN=1 (288 CE cycles)  
1 + MUX_DIV * 3, if FIR_LEN=2 (384 CE cycles).  
An ADC conversion will always consume an integer number of CK32 clocks. Following this is a single  
CK32 cycle where the bandgap voltage is allowed to recover from the change in CROSS.  
ADC MUX Frame  
MUX_DIV=4 (4 conversions) is shown  
Settle  
ADC TIMING  
CK32  
150  
0
MUX_SYNC  
MUX STATE  
S
1
2
3
S
ADC EXECUTION  
ADC0  
450  
ADC1  
900  
ADC2  
1350  
ADC3  
1800  
CE TIMING  
0
CE_EXECUTION  
CK COUNT = CE_CYCLES + floor((CE_CYCLES + 2) / 5)  
MAX CK COUNT  
CE_BUSY  
XFER_BUSY  
INITIATED BY A CE OPCODE AT END OF SUMMATION INTERVAL  
NOTES:  
1. ALL DIMENSIONS ARE 5MHZ CK COUNTS.  
2. THE PRECISE FREQUENCY OF CK IS 150*CRYSTAL FREQUENCY = 4.9152MHz.  
3. XFER_BUSY OCCURS ONCE EVERY (PRE_SAMPS * SUM_CYCLES) CODE PASSES.  
Figure 19: Timing Relationship between ADC MUX, Compute Engine  
Each CE program pass begins when the ADC0 conversion (for IA) begins. Depending on the length of  
the CE program, it may continue running until the end of the last conversion (ADC3). CE opcodes are  
constructed to ensure that all CE code passes consume exactly the same number of cycles. The result of  
each ADC conversion is inserted into the RAM when the conversion is complete. The CE code is written  
to tolerate sudden changes in ADC data. The exact clock count when each ADC value is loaded into  
RAM is shown in Figure 19.  
Figure 20 shows that the serial data stream, RTM, begins transmitting at the beginning of state S. RTM,  
consisting of 140 CK cycles, will always finish before the next code pass starts.  
CK32  
MUX_SYNC  
CKTEST  
0
1
0
1
0
1
0
1
30  
30 31  
30 31  
30 31  
31  
TMUXOUT/RTM  
FLAG  
FLAG  
FLAG  
FLAG  
LSB  
SIGN  
LSB  
LSB  
LSB  
RTM DATA 0 (32 bits)  
RTM DATA 1 (32 bits)  
RTM DATA 2 (32 bits)  
RTM DATA 3 (32 bits)  
SIGN  
SIGN  
SIGN  
Figure 20: RTM Output Format  
2.3  
Battery Modes  
Shortly after system power (V3P3SYS) is applied, the part will be in MISSION mode. MISSION mode  
means that the part is operating with system power and that the internal PLL is stable. This mode is the  
normal operation mode where the part is capable of measuring energy.  
54  
© 2005-2009 TERIDIAN Semiconductor Corporation  
v1.2