JANUARY 2008  
On-chip hardware provides a maximum pulse width feature: PLS_MAXWIDTH[7:0] selects a maximum negative pulse width to  
be ‘Nmax’ updates according to the formula: Nmax = (2*PLS_MAXWIDTH+1). If PLS_MAXWIDTH = 255, no width checking is  
performed.  
Given that PLS_INTERVAL = 81, the maximum pulse width is determined by:  
Maximum Pulse Width = (2 * PLS_MAXWIDTH +1) * 81*4*203ns = 65.8µs + PLS_MAXWIDTH * 131.5µs  
The CE pulse output polarity is programmable to be either positive or negative. Pulse polarity may be inverted with PLS_INV.  
When this bit is set, the pulses are active high, rather than the more usual active low.  
CE Functional Overview  
The ADC processes one sample per channel per multiplexer cycle. Figure 4 shows the timing of the samples taken during one  
multiplexer cycle.  
The number of samples processed during one accumulation cycle is controlled by the I/O RAM registers PRE_SAMPS  
(0x2001[7:6]) and SUM_CYCLES (0x2001[5:0]). The integration time for each energy output is  
PRE_SAMPS * SUM_CYCLES / 2520.6, where 2520.6 is the sample rate [Hz]  
For example, PRE_SAMPS = 42 and SUM_CYCLES = 50 will establish 2100 samples per accumulation cycle. PRE_SAMPS = 100  
and SUM_CYCLES = 21 will result in the exact same accumulation cycle of 2100 samples or 833ms. After an accumulation  
cycle is completed, the XFER_BUSY interrupt signals to the MPU that accumulated data are available.  
1/32768Hz =  
30.518µs  
IB  
VB  
IA  
VA  
13/32768Hz = 397µs  
per mux cycle  
Figure 4: Samples from Multiplexer Cycle  
The end of each multiplexer cycle is signaled to the MPU by the CE_BUSY interrupt. At the end of each multiplexer cycle,  
status information, such as sag data and the digitized input signal, is available to the MPU.  