 浏览型号71M6515H-IGTR/F的Datasheet PDF文件第41页浏览型号71M6515H-IGTR/F的Datasheet PDF文件第42页浏览型号71M6515H-IGTR/F的Datasheet PDF文件第43页浏览型号71M6515H-IGTR/F的Datasheet PDF文件第44页浏览型号71M6515H-IGTR/F的Datasheet PDF文件第46页浏览型号71M6515H-IGTR/F的Datasheet PDF文件第47页浏览型号71M6515H-IGTR/F的Datasheet PDF文件第48页浏览型号71M6515H-IGTR/F的Datasheet PDF文件第49页  
71M6515H  
Energy Meter IC  
DATA SHEET  
MARCH 2008  
520  
520  
V _ PTHRESHOLD =  
I _ PTHRESHOLD =  
=
= 14,893  
= 33,046  
450.76 106600  
LSB  
SUM _ CYCLES  
400  
400  
=
450.76 106 208  
LSB  
SUM _ CYCLES  
Registers Controlling Time and RTC Functions  
OP_TIME (0x1E)  
This register holds the operating time expressed in 1/100 hours. The register will be reset to zero whenever the host writes  
time or date to the RTC.  
RTC_DATE (0x20)  
This register holds the date information provided by the RTC. The register can be written to in order to set the date.  
Bits 15-8: These bits contain the year information (0 to 255). The value 0 represents the year 2000.  
Bits 23-16: These bits contain the month information (01 to 12). The value 01 represents January.  
Bits 31-24: These bits contain the day of month information (01 to 31).  
RTC_TIME_DAY (0x1F)  
This register holds the time and day information provided by the RTC. The register can be written to in order to set the  
time.  
Bits 7-0: These bits contain the day of the week (01 to 07). The value 01 represents Sunday.  
Bits 15-8: These bits contain the hour information (00 to 23). The value 00 represents midnight.  
Bits 23-16: These bits contain the minutes information (00 to 59).  
Bits 31-24: These bits contain the seconds information (00 to 59).  
Example: The value 200835 is read from the OP_TIME register. This means that the meter has been running  
since the last reset or power-up for  
t = 800850/100h = 8008.50h or 8,008h and 30 minutes (333.6875 days or 333 days and 16.5h).  
Registers Used for Test Functions  
RTM (0x21)  
This register controls the Real-Time Monitor. When the RTM_EN bit in the CONFIG register is set, the values of CE RAM  
locations specified with the RTM register can be routed to the TMUX pin as a serial data stream. The TMUX bits in the  
CONFIG register must be set to 3 in order to select the RTM output for the TMUX pin.  
Bits 7-0: These bits (RTM3) select the CE address for RTM3.  
Bits 15-8:. These bits (RTM2) select the CE address for RTM2.  
Bits 23-16: These bits (RTM1) select the CE address for RTM1.  
Bits 31-24: These bits (RTM0) select the CE address for RTM0.  