4.3.2 Groups C and D inspections.
a. End-point electrical parameters shall be as specified in table II herein.
b. Steady-state life test conditions, method 1005 of MIL-STD-883.
(1) Test condition C or D. The test circuit shall be maintained by the manufacturer under document revision level
control and shall be made available to the preparing or procuring activity upon request. The test circuit shall specify
the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in test
method 1005 of MIL-STD-883.
(2) TA = +125 C, minimum.
(3) Test duration: 1,000 hours, except as permitted by method 1005 of MIL-STD-883.
TABLE II. Electrical test requirements.
MIL-STD-883 test requirements
Subgroups (per method 5005, table I)
- - -
Interim electrical parameters (method 5004)
Final electrical test parameters
(method 5004)
1*, 2, 3, 7*, 8A, 8B, 9, 10, 11
1, 2, 3, 4**, 7, 8A, 8B, 9, 10, 11
Group A test requirements (method 5005)
Groups C and D end-point electrical
parameters (method 5005)
2, 3, 7, 8A, 8B
* Indicates PDA applies to subgroups 1 and 7.
** See 4.3.1c.
5. PACKAGING
5.1 Packaging requirements. The requirements for packaging shall be in accordance with MIL-PRF-38535, appendix A.
6. NOTES
6.1 Intended use. Microcircuits conforming to this drawing are intended for use for government microcircuit applications
(original equipment), design applications, and logistics purposes.
6.2 Replaceability. Microcircuits covered by this drawing will replace the same generic device covered by a contractor-
prepared specification or drawing.
6.3 Configuration control of SMD's. All proposed changes to existing SMD's will be coordinated with the users of record for
the individual documents. This coordination will be accomplished using DD Form 1692, Engineering Change Proposal.
6.4 Record of users. Military and industrial users should inform Defense Supply Center Columbus when a system application
requires configuration control and which SMD's are applicable to that system. DSCC will maintain a record of users and this list
will be used for coordination and distribution of changes to the drawings. Users of drawings covering microelectronic devices
(FSC 5962) should contact DSCC-VA, telephone (614) 692-0525.
6.5 Comments. Comments on this drawing should be directed to DSCC-VA, Columbus, Ohio 43216-5000, or telephone 614-
692-0674.
6.6 Approved source of supply. An approved source of supply is listed herein. Additional sources will be added as they
become available. The vendor listed herein has agreed to this drawing and a certificate of compliance (see 3.6 herein ) has
been submitted to DSCC-VA.
SIZE
STANDARD
5962-89567
A
MICROCIRCUIT DRAWING
REVISION LEVEL
A
SHEET
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43216-5000
18
DSCC FORM 2234
APR 97