Data Sheets  
Sensitive SCRs  
140  
120  
100  
130  
120  
110  
100  
90  
CURRENT WAVEFORM: Sinusoidal  
LOAD: Resistive or Inductive  
CONDUCTION ANGLE: 180  
CURRENT WAVEFORM: Sinusoidal  
LOAD: Resistive or Inductive  
˚
CONDUCTION ANGLE: 180  
CASE TEMPERATURE: Measured  
as Shown on Dimensional Drawing  
FREE AIR RATING  
˚
T106/T107 TO-202  
Type 1 and 3  
80  
60  
80  
70  
T106 and T107  
Type 2 and 4  
T106 and T107  
Type 1 and 3  
60  
TCR22  
Devices  
TO-220  
40  
20  
50  
T106/T107 TO-202  
Type 2 and 4  
and TO-251  
40  
0.95  
1.65  
1.9  
2.54  
0
0.5  
1.0  
1.5  
2.0  
2.5  
3.0  
0
0.2  
0.4  
0.6  
0.8  
1.0  
1.2  
1.4  
Average On-state Current [I  
] – Amps  
T(AV)  
Average On-state Current [I  
] – Amps  
T(AV)  
Figure E5.4 Maximum Allowable Case Temperature versus  
Average On-state Current  
Figure E5.7 Maximum Allowable Ambient Temperature versus  
Average On-state Current  
140  
CURRENT WAVEFORM: Sinusoidal  
LOAD: Resistive or Inductive  
115  
CURRENT WAVEFORM: Sinusoidal  
LOAD: Resistive or Inductive  
120  
100  
CONDUCTION ANGLE: 180  
FREE AIR RATING  
˚
110  
6 A TO-251  
and TO-252  
CONDUCTION ANGLE: 180  
˚
TEMPERATURE: Measured as  
Shown on Dimensional Drawings  
105  
100  
95  
8 A TO-251  
and TO-252  
10 A TO-251  
and TO-252  
EC Series I  
T(RMS)  
6 A TO-220  
and TO-202  
80  
60  
40  
20  
1.5 A Devices  
and JEDEC  
2N Series I  
8 A TO-220  
and TO-202  
T(RMS)  
90  
1.5 A and JEDEC  
2N Series I  
T(AV)  
85  
80  
10 A TO-220  
and TO-202  
and EC Series I  
T(AV)  
0
2
4
6
8
10  
RMS On-state Current [I  
] – Amps  
T(RMS)  
0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9  
On-state Current – Amps  
Figure E5.5 Maximum Allowable Ambient Temperature versus  
On-state Current  
Figure E5.8 Maximum Allowable Case Temperature versus  
RMS On-state Current  
140  
CURRENT WAVEFORM: Sinusoidal  
LOAD: Resistive or Inductive  
110  
CURRENT WAVEFORM: Sinusoidal  
LOAD: Resistive or Inductive  
6 A TO-251  
and TO-252  
120  
CONDUCTION ANGLE: 180  
˚
CONDUCTION ANGLE: 180  
CASE TEMPERATURE: Measured  
as Shown on Dimensional Drawings  
FREE AIR RATING  
105  
˚
100  
100  
95  
6 A TO-220  
and TO-202  
80  
60  
40  
20  
T106/T107 TO-202  
Type 1 and 3  
8 A TO-251  
and TO-252  
8 A TO-220  
and TO-202  
90  
85  
T106/T107 TO-202  
Type 2 and 4  
and TO-251  
10 A TO-251  
and TO-252  
TO-220  
10 A TO-220  
and TO-202  
80  
0
0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0  
0
1
2
3
4
5
6
7
Average On-state Current [I  
] – Amps  
T(AV)  
RMS On-state Current [I  
] – Amps  
T(RMS)  
Figure E5.6 Maximum Allowable Ambient Temperature versus  
RMS On-state Current  
Figure E5.9 Maximum Allowable Case Temperature versus  
Average On-state Current  
©2002 Teccor Electronics  
Thyristor Product Catalog  
E5 - 7  
http://www.teccor.com  
+1 972-580-7777  
 复制成功!