TCS3404, TCS3414
DIGITAL COLOR SENSORS
TAOS137A − APRIL 2011
Terminal Functions
TERMINAL
TYPE
DESCRIPTION
CS PKG FN PKG
NAME
GND
NO.
A3
B3
A1
B1
A2
B2
NO.
6
Power supply ground. All voltages are referenced to GND.
Level interrupt — open drain.
INT
4
O
I
2
SCL
SDA
SYNC
1
Serial clock input terminal — clock signal for I C serial data.
2
3
I/O
I
Serial data I/O terminal — serial data I/O for I C.
2
Synchronous input.
Supply voltage.
V
5
DD
Available Options
2
DEVICE
TCS3404
TCS3404
TCS3413
TCS3413
INTERFACE
SMBus
I C ADDRESS
PACKAGE − LEADS
Chipscale−6
PACKAGE DESIGNATOR
ORDERING NUMBER
TCS3404CS
TCS3404FN
TCS3413CS
TCS3413FN
TCS3414CS
TCS3414FN
TCS3415CS
TCS3415FN
TCS3416CS
TCS3416FN
−
CS
FN
CS
FN
CS
FN
CS
FN
CS
FN
SMBus
−
Dual Flat No-Lead−6
Chipscale−6
2
I C
0x29
0x29
0x39
0x39
0x49
0x49
0x59
0x59
2
I C
Dual Flat No-Lead−6
Chipscale−6
†
2
TCS3414
TCS3414
I C
†
2
I C
Dual Flat No-Lead−6
Chipscale−6
2
TCS3415
TCS3415
TCS3416
TCS3416
I C
2
I C
Dual Flat No-Lead−6
Chipscale−6
2
I C
2
I C
Dual Flat No-Lead−6
†
Recommended device for single-device systems..
Absolute Maximum Ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage, V (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.8 V
DD
Digital output voltage range, V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −0.5 V to 3.8 V
O
Digital output current, I . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −1 mA to 20 mA
O
Storage temperature range, T
ESD tolerance, human body model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2000 V
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . −40°C to 85°C
stg
†
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: All voltages are with respect to GND.
Recommended Operating Conditions
MIN NOM
MAX
3.6
UNIT
V
Supply voltage, V
2.7
3
DD
Operating free-air temperature, T (CS PAckage)
−40
85
°C
A
Operating free-air temperature, T (FN PAckage)
−30
−0.5
2.1
70
0.8
3.6
°C
V
A
SCL, SDA input low voltage, V
IL
SCL, SDA input high voltage, V
V
IH
Copyright E 2011, TAOS Inc.
The LUMENOLOGY r Company
r
r
www.taosinc.com
3