W681308  
Value At  
Function  
Reset  
Address  
Name  
Mode  
R/W  
R/W  
0x1807 ~  
0x1809  
USB Interrupt Register  
C
0x00  
0x00  
Set USB Audio Class interrupt enable, status and clear.  
Set USB Control in/out Endpoint control  
Endpoint 0 – Control  
In/Out  
0x1810  
Control in Endpoint Data. Internal FIFO has 1 byte for  
Control In transmission. If the 3rd Token byte is not equal  
to 0x01 or 0x03 (HID set report application), this byte will  
be transmitted instead of Control-IN FIFO and Interrupt-  
IN FIFO content.  
0x1811  
Control In Data  
R/W  
0x00  
0x1828 ~  
0x182F  
Control Out Data  
R
R/W  
R
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
0x00  
Control Out Endpoint receiving data.  
Set ISO In/Out Endpoint control register.  
Indicate ISO Sampling Frequency  
Indicate Current Record Volume  
Indicate Current Play Volume  
Endpoint 1 and 2 –  
ISO In/Out  
0x1830  
0x1831  
Sampling Frequency  
Record Volume  
Play Volume  
0x1832-  
0x1833  
R
0x1834-  
0x1835  
R
HID Control Out  
Information  
0x1836  
0x1837  
0x1838  
0x1839  
R
Indicate First Packet and Valid Length  
Indicate Audio Path Max Volume Gain  
Set HID Token 3rd byte  
Max Volume  
R
HID Token Information  
HID Descriptor Length  
ISO SYNC Speed  
R/W  
R/W  
R/W  
R/W  
W
This register value must be equal to the USB descriptor  
with respect to the HID return length  
0x1840 ~  
0x1847  
Set ISO SYNC speed tuning parameter register.  
Set Bulk In Endpoint control register  
Endpoint 3 – Bulk In  
Control Register  
0x1848  
0x1849  
0x184A  
0x184B  
0x1850  
Bulk In Data  
Set Bulk In transmission data register except final data.  
Set Bulk In transmission final data register.  
Indicate Bulk In transmission data FIFO empty flag.  
Set Bulk Out Endpoint control register  
Bulk In Final Data  
W
Bulk In FIFO Empty  
Flag  
R
Endpoint 4 – Bulk Out  
Control Register  
R/W  
19  
Rev1.2  