17. High Temperature Loading
Appearance
: No abnormality
Capacitance change
Q
: Within ±3% or ±0.3pF, whichever is larger.
: C<10pF: Q≧200+10C
Standard
10≦C<30pF:Q≧275+2.5C
C≧30pF: Q≧350(C:Nominal capacitance)
: 1000 MΩ min.
Temperature
Compensating(Class1)
Insulation resistance
Appearance
: No abnormality
Specified
Value
High Frequency Type Capacitance change
Insulation resistance
: Within ±3% or ±0.3pF, whichever is larger.
: 1000 MΩ min.
Appearance
: No abnormality
Capacitance change
: Within ±12.5% (BJ, B7, C6, C7, LD(※))
Within ±30% (F)
High Permittivity (Class2) Note 1
Dissipation factor
: 5.0% max.(BJ, B7, C6, C7, LD(※))
11.0% max.(F)
Insulation resistance
: 50 MΩμF or 1000 MΩ, whichever is smaller.
Note: ※LD Low distortion high value multilayer ceramic capacitor
Class 1
High Frequency Type
Class 2
C6
Standard
BJ, LD(※), F
B7, C7
Voltage treatment(Twice the rated voltage shall be applied for
1 hour at 85℃, 105℃ or 125℃) Note 3, 4
Maximum operating temperature
Preconditioning
None
Temperature
Duration
Maximum operating temperature
1000+48/-0 hrs
Test
1000+48/-0 hrs
Methods and
Remarks
Applied voltage
Charge/discharge
current
Rated voltage×2
Rated voltage×2 Note 4
50mA max.
50mA max.
Recovery
6 to 24hr (Standard condition) Note 5
24±2 hrs (Standard condition) Note 5
Note: ※LD Low distortion high value multilayer ceramic capacitor
Note 1 The figures indicate typical specifications. Please refer to individual specifications in detail.
Note 2 Thermal treatment : Initial value shall be measured after test sample is heat-treated at 150+0/-10℃ for an hour and kept at room temperature for
24±2hours.
Note 3 Voltage treatment : Initial value shall be measured after test sample is voltage-treated for an hour at both the temperature and voltage specified in
the test conditions, and kept at room temperature for 24±2hours.
Note 4 150% of rated voltage is applicable to some items. Please refer to their specifications for further information.
Note 5 Standard condition: Temperature: 5 to 35℃, Relative humidity: 45 to 85 % RH, Air pressure: 86 to 106kPa When there are questions concerning
measurement results, in order to provide correlation data, the test shall be conducted under the following condition.
Temperature: 20±2℃, Relative humidity: 60 to 70 % RH, Air pressure: 86 to 106kPa Unless otherwise specified, all the tests are conducted under the
"standard condition".
▶ This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) .
c_mlcc_reli_e-01