6. Capacitance (Tolerance)
Temperature
0.2pF≦C≦5pF
0.2pF≦C≦10pF
C>10pF
: ±0.25pF
C□
U□
SL
Standard
: ±0.5pF
: ±5% or ±10%
Compensating(Class1)
Specified
Value
0.3pF≦C≦2pF
C>2pF
: ±0.1pF
: ±5%
CH
RH
High Frequency Type
BJ, B7, C6, C7, LD(※) : ±10% or ±20%,
F : +80/-20%
High Permittivity (Class2)
Note: ※LD Low distortion high value multilayer ceramic capacitor
Class 1
High Frequency Type
Class 2
Standard
C≦10μF
C>10μF
Test
Preconditioning
None
Thermal treatment (at 150℃ for 1hr) Note 2
Methods and
Remarks
Measuring frequency
Measuring voltage Note
Bias application
1MHz±10%
0.5 to 5Vrms
1kHz±10%
1±0.2Vrms
120±10Hz
0.5±0.1rms
one
7. Q or Dissipation Factor
C<30pF : Q≧400+20C
C≧30pF : Q≧1000
Standard
Temperature
Compensating(Class1)
(C:Nominal capacitance)
Specified
Value
High Frequency Type Refer to detailed specification
High Permittivity (Class2) Note 1
BJ, B7, C6, C7:2.5% max., F:7% max.
Class 1
Class 2
Standard
High Frequency Type
C≦10μF
C>10μF
Preconditioning
None
Thermal treatment (at 150℃ for 1hr) Note 2
Test
Measuring frequey
Measuring voltage Note 1
Bias application
1MHz±10%
1GHz
1kHz±10%
1±0.2Vrms
120±10Hz
Methods and
Remarks
0.5 to 5Vrms
0.5±0.1Vrms
None
High Frequency Type
Measuring equipment
Measuring jig
: HP4291A
: HP16192A
8. Temperature Characteristic (Without voltage application)
Temperature Characteristic [ppm/℃]
Tolerance [ppm/℃]
C□ :
0
CH, CJ, CK
H : ±60
J : ±120
K : ±250
Standard
U□ : -750
UJ, UK
Temperature
SL : +350 to -1000
Compensating(Class1)
Temperature Characteristic [ppm/℃]
Tolerance [ppm/℃]
H : ±60
High Frequency Type
C□ :
0
CH
RH
R□ : -220
Capacitance
change
Reference
Specified
Value
Specification
Temperature Range
temperature
20℃
B
±10%
-25 to +85℃
-55 to +85℃
-55 to +125℃
-55 to +105℃
-55 to +125℃
-55 to +85℃
-25 to +85℃
-30 to +85℃
BJ
X5R
X7R
X6S
X7S
X5R
F
±15%
25℃
B7
C6
±15%
25℃
High Permittivity (Class2)
±22%
25℃
C7
±22%
25℃
LD(※)
±15%
25℃
+30/-80%
+22/-82%
20℃
F
Y5V
25℃
Note : ※LD Low distortion high value multilayer ceramic capacitor
Class 1
Capacitance at 20℃ and 85℃ shall be measured in thermal equilibrium, and the temperature characteristic shall be calculated from the
following equation.
(C85-C20)
×106(ppm/℃)
C20×△T
△T=65
Test
Class 2
Methods and
Remarks
Capacitance at each step shall be measured in thermal equilibrium, and the temperature characteristic shall be calculated from the following
equation.
Step
B、F
X5R、X7R、X6S、X7S、Y5V
Minimum operating temperature
1
2
3
20℃
25℃
Maximum operating temperature
▶ This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) .
c_mlcc_reli_e-01