■ RELIABILITY DATA
12.Temperature Cycle(Thermal Shock)
Appearance: No abnormality
Capacitance change: ±2.5% max
Dissipation factor : Initial value
Specified Value
Insulation resistance: Initial value
Withstanding voltage(between terminals): No abnormality
【Test Methods and Remarks】
+0
Conditions for 1 cycle/ Step 1: Minimum operating temperature
℃
30±3 min.
-3
Step 2: Normal temperature
Step 3: Maximum operating temperature
Step 4: Normal temperature
2 to 3 min.
+0
-3
℃
30±3 min.
2 to 3 min.
Number of cycles: 5 times
Measurement shall be conducted : 24±2hrs under the standard condition
Note1
13.Humidity(Steady state)
Appearance: No abnormality
Capacitance change: ±5% max
Dissipation factor : 0.5% max
Specified Value
Insulation resistance 50MΩμF or 1000MΩ, whichever is smaller
【Test Methods and Remarks】
Temperature:40±2℃
Humidity:90 to 95% RH
+24
Duration:500
hrs
-0
Measurement shall be conducted : 24 ±2hrs under the standard condition
Note1
14.Humidity Loading
Appearance: No abnormality
Capacitance change: ±7.5% max
Dissipation factor : 0.5% max
Specified Value
Insulation resistance: 25MΩμF or 500MΩ, whichever is smaller
【Test Methods and Remarks】
According to JIS C 5102 clause 9.9.
Temperature:40±2℃ꢀHumidity:90 to 95% RH
+24
Duration:500
hrs
-0
Applied voltage: Rated voltage
Charge/discharge current:50mA max
Measurement shall be conducted : 24 ±2hrs under the standard condition
Note1
15.High Temperature Loading
Appearance: No abnormality
Capacitance change: ±3% max
Dissipation factor : 0.35% max
Specified Value
Insulation resistance: 50MΩμF or 1000MΩ, whichever is smaller
【Test Methods and Remarks】
According to JIS C 5102 clause 9.10.
Temperature:125±3℃
+48
Duration:1000
hrs
-0
Applied voltage: Rated voltage x 2
Charge/discharge current:50mA max
Measurement shall be conducted : 24 ±2hrs under the standard condition Note1
Note1
Standard condition: Temperature: 5 to 35℃, Relative humidity: 45 to 85 % RH, Air pressure: 86 to 106kPa
When there are questions concerning measurement results, in order to provide correlation data, the test shall be conducted under the following condition.
Temperature: 20±2℃, Relative humidity: 60 to 70 % RH, Air pressure: 86 to 106kPa
Unless otherwise specified, all the tests are conducted under the "standard condition".
*This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs.
mlcc05_reli_e-01
mlcc05_reli-R2