HV232
Electrical Characteristics
AC Characteristics (over operating conditions VDD = 5V, unless otherwise noted)
0°C
+25°C
+70°C
max
Characteristics
Sym
Units
Test Conditions
min
150
150
55
max
min
150
150
60
typ
max
min
150
150
70
Set Up Time Before LE Rises
Time Width of LE
tSD
tWLE
tDO
tWCL
tSU
ns
ns
Clock Delay Time to Data Out
Time Width of CL
150
150
150
ns
150
15
150
15
150
20
ns
Set Up Time Data to Clock
Hold Time Data from Clock
Clock Freq
8.0
ns
th
35
35
35
ns
fCLK
5.0
5.0
5.0
MHz
50% duty cycle
f
DATA = fCLK/2
Clock Rise and Fall Times
Turn On Time
tr, tf
tON
1.0
5.0
1.0
5.0
1.0
5.0
µs
µs
VSIG = VPP -10V,
RL = 10KΩ
Turn Off Time
tOFF
dv/dt
KO
5.0
20
20
20
5.0
20
20
20
5.0
20
20
20
µs
VSIG = VPP -10V,
RL = 10KΩ
V
PP = 160V,
VNN = -40V
Maximum VSIG Slew Rate
V/ns
VPP = 100V,
VNN = -100V
V
PP = 40V,
VNN = -160V
Off Isolation
-30
-58
-60
-30
-58
-60
-33
-70
-30
-58
-60
dB
dB
dB
mA
f = 5MHz,
1KΩ//15pF load
f = 5MHz,
50Ω load
Switch Crosstalk
KCR
IID
f = 5MHz,
50Ω load
Output Switch Isolation
Diode Current
300
300
300
300ns pulse width,
2.0% duty cycle
Off Capacitance SW to GND
On Capacitance SW to GND
CSG(OFF)
CSG(ON)
5.0
25
17
50
5.0
25
12
38
17
50
5.0
25
17
50
pF
pF
0V, 1MHz
0V, 1MHz