HV232
Electrical Characteristics
DC Characteristics (over recommended operating conditions unless otherwise noted)
0°C
min
+25°C
typ
+70°C
min max
Characteristics
Sym
Units Test Conditions
max
30
min
max
38
26
22
22
18
20
16
5.0
48
32
30
27
30
27
20
ISIG = 5mA
SIG = 200mA VNN = -160V
ohms ISIG = 5mA VPP = 100V,
ISIG = 200mA VNN = -100V
VPP = 40V,
25
27
I
Small Signal Switch (ON)
Resistance
RONS
25
18
27
24
23
25
I
I
SIG = 5mA
VPP = 160V,
22
25
SIG = 200mA VNN = -40V
Small Signal Switch (ON)
Resistance Matching
∆RONS
20
20
%
ISW = 5mA, VPP = 100V,
NN = -100V
V
Large Signal Switch (ON)
Resistance
RONL
15
35
ohms VSIG = VPP - 10V, ISIG = 1A
Output Switch Shunt
Resistance
RINT
20
50
10
KΩ
µA
Output switch to RGND
VSIG = VPP - 10V
Switch Off Leakage
Per Switch
ISOL
5.0
1.0
15
DC Offset Switch Off
300
500
100
100
10
300
500
50
300
500
mV
mV
µA
µA
µA
µA
A
No Load
DC Offset Switch On
No Load
Pos. HV Supply Current
Neg. HV Supply Current
Pos. HV Supply Current
Neg. HV Supply Current
IPPQ
INNQ
IPPQ
INNQ
ALL SWs OFF
-10
10
-50
50
ALL SWs OFF
ALL SWs ON, ISW = 5mA
ALL SWs ON, ISW = 5mA
VSIG duty cycle ≤ 0.1%
-10
3.0
-50
2.0
Switch Output
Peak Current
3.0
2.0
Output Switch Frequency
fSW
50
KHz
mA
Duty Cycle = 50%
6.5
4.0
4.0
6.5
4.0
4.0
4.0
10
7.0
8.0
5.5
5.5
8.0
5.5
5.5
4.0
10
VPP = 40V,
VNN = -160V
IPP Supply Current
IPP
5.0
5.0
7.0
5.0
5.0
4.0
10
VPP = 100V,
VNN = -100V
50KHz
VPP = 160V,
VNN = -40V
Output
Switching
Frequency
with no
VPP = 40V,
VNN = -160V
load
INN Supply Current
INN
mA
VPP = 100V,
VNN = -100V
VPP = 160V,
VNN = -40V
Logic Supply
Average Current
IDD
mA
fCLK = 5MHz, VDD = 5.0V
Logic Supply
IDDQ
µA
Quiescent Current
Data Out Source Current
Data Out Sink Current
Logic Input Capacitance
ISOR
ISINK
CIN
0.45
0.45
0.45
0.45
0.70
0.70
0.40
0.40
10
mA
mA
pF
VOUT = VDD - 0.7V
VOUT = 0.7V
10
10
2