HV2116
Electrical Characteristics
AC Characteristics
(over operating conditions V
DD
= 15V, unless otherwise noted)
Characteristics
Sym
+V
SPK
-V
SPK
Output Voltage Spike
+V
SPK
-V
SPK
+V
SPK
-V
SPK
Charge Injection
Q
+25
°
C
min
typ
1.0
3.5
12
18
6.0
9.0
1700
850
600
pC
V
max
Units
Test Conditions
V
PP
= 40V, V
NN
= -120V
R
L
= 50Ω
V
PP
= 80V, V
NN
= -80V
R
L
= 50Ω
V
PP
= 150V, V
NN
= -10V
R
L
= 50Ω
V
PP
= 80V, V
NN
= -80V, V
SIG
= 0V
V
PP
= 80V, V
NN
= -80V, V
SIG
= 70V
V
PP
= 80V, V
NN
= -80V, V
SIG
= -70V
TE –
SOLE
– OB
Operating Conditions
Symbol
V
DD
V
PP
V
NN
V
IH
V
IL
V
SIG
T
A
Parameter
Logic power supply voltage
1, 3
Positive high voltage supply
1, 3
Negative high voltage supply
1, 3
High-level input voltage
Low-level input voltage
Analog signal voltage peak to peak
2
Operating free air-temperature
Value
10.0 V to 15.5 V
40V to V
NN
+ 160V
-10.0V to -120V
V
DD
-2V to V
DD
0V to 2.0V
V
NN
+10V to V
PP
-10
0°C to 70°C
Notes:
1 Power up/down sequence is arbitrary except GND must be powered-up first and powered-down last.
2 V
SIG
must be V
NN
≤
V
SIG
≤
V
PP
or floating during power up/down transistion.
3 Rise and fall times of power supplies V
DD
, V
PP
, and V
NN
should not be less than 1.0msec.
13-60