HV111
Ordering Information
Package Options
DEVICE
DPAK-5
HV111
HV111K4
Absolute Maximum Ratings
Supply Voltage*, V
pp
Operating Temperature Range
Storage Temperature Range
5 Pin DPAK Thermal Resistance R
θ
JA
5 Pin DPAK Thermal Resistance R
θ
JC
* Relative to V
NN
-0.5V to 90V
-40°C to +85°C
-65° to +150°C
80°C/W
11°C/W
Electrical Characteristics
( * means -20°C< T < +85°C)
A
Symbol
Parameter
Min
Typ
Max
Units
T
A
Conditions
V
PP
I
PP
V
UVLO
V
HYS
V
UV
V
UVHYS
R
UVLO
R
DS
I
LEAK
I
INRUSH
I
CB
I
LIMIT
I
SC
VOL
PWRGD
IOH
PWRGD
t
SC
t
OC
t
LIMIT
t
POR
t
RESTART
T
OVER
T
RESET
Supply Voltage
Supply Current
Internal UVLO Threshold (High to
Low ie. Turning Off)
Internal UVLO Hysteresis
UVLO Comparator Threshold
UVLO Comparator Hysteresis
UVLO Input Resistance
MOSFET On Resistance
Output Leakage Current
Inrush Current Limit
Circuit Breaker Trip Current
Over Load Current Limiting
Shorted Circuit PWM Average
Current
PWRGD Output Low Voltage
PWRGD Output leakage Current
Shorted-Circuit Timer
Over-Current Timer
Current Limit Delay Time
POR Timer
Restart Timer (4)
Over Temperature Trip Point
Temperature Reset
(1) (4)
(2) (4)
(3)
-80
-23.5
1.5
1.10
60
78
-26.0
2.5
1.20
100
111
1
1.15
1.65
1.40
2.00
1.2
230
-8.0
1
-28.5
3.5
1.30
140
144
1.5
10
1.65
2.35
V
mA
V
V
V
mV
kΩ
Ω
µA
A
*
*
*
*
*
*
*
*
*
V
PP
– V
NN
V
NN
= -48V, Standby Mode
Subtract V
HYS
for Low-to-High
Referenced to V
NN
MOSFET is off
Trips then limits to I
LIMIT
until toc
expires.
V
PP
-V
DRAIN
< ~1V
I=1mA; Reference to V
NN
A
mA
0.4
10
V
µA
ms
ms
µs
6.5
150
100
ms
Sec
°C
°C
*
*
*
*
*
*
*
*
*
V=5V; Reference to V
NN
40
40
75
75
10
110
110
Limits within 10µs. May take
up to 100µs to reach final level.
2.5
120
70
4.5
9
135
Low to High
High to Low
(1) Shorted-circuit timer starts after POR timer. If V
DS
drops more than ¼(V
PP
-V
NN
) after t
SC
then a shorted-circuit condition exists.
(2) If the output current is in an overload condition then the output immediately goes to current limit and starts the over-current timer. If I
OUT
does not drop back
below I
LIMIT
before the timer expires then an over current condition exists. The timer is immediately reset when a fault is cleared.
(3) Time for fast return to limit circuit to react.
(4) Guaranteed by design.
2