 浏览型号STM8S207R8T6BTR的Datasheet PDF文件第58页浏览型号STM8S207R8T6BTR的Datasheet PDF文件第59页浏览型号STM8S207R8T6BTR的Datasheet PDF文件第60页浏览型号STM8S207R8T6BTR的Datasheet PDF文件第61页浏览型号STM8S207R8T6BTR的Datasheet PDF文件第63页浏览型号STM8S207R8T6BTR的Datasheet PDF文件第64页浏览型号STM8S207R8T6BTR的Datasheet PDF文件第65页浏览型号STM8S207R8T6BTR的Datasheet PDF文件第66页  
Electrical characteristics  
STM8S207xx, STM8S208xx  
Total current consumption in halt mode  
Table 26. Total current consumption in halt mode at V = 5 V, T -40 to 85° C  
DD  
A
Symbol  
Parameter  
Conditions  
Typ  
Max  
Unit  
Flash in operating mode, HSI  
clock after wakeup  
63.5  
IDD(H)  
Supply current in halt mode  
µA  
Flash in powerdown mode, HSI  
clock after wakeup  
6.5  
35  
Table 27. Total current consumption in halt mode at V = 3.3 V  
DD  
Symbol  
Parameter  
Conditions  
Typ  
Unit  
Flash in operating mode, HSI clock after  
wakeup  
61.5  
IDD(H)  
Supply current in halt mode  
µA  
Flash in powerdown mode, HSI clock after  
wakeup  
4.5  
Low power mode wakeup times  
Table 28. Wakeup times  
Symbol  
Parameter  
Conditions  
Typ  
Max(1) Unit  
See  
note(2)  
Wakeup time from wait  
mode to run mode(3)  
tWU(WFI)  
f
CPU = fMASTER = 16 MHz.  
0.56  
1(6)  
Flash in operating  
mode(5)  
2(6)  
MVR voltage  
regulator on(4)  
Flash in  
powerdown  
3(6)  
48(6)  
50(6)  
mode(5)  
Wakeup time active halt  
mode to run mode.(3)  
HSI (after  
wakeup)  
µs  
tWU(AH)  
Flash in operating  
mode(5)  
MVR voltage  
regulator off(4)  
Flash in  
powerdown  
mode(5)  
Flash in operating mode(5)  
Flash in powerdown mode(5)  
52  
54  
Wakeup time from halt  
mode to run mode(3)  
tWU(H)  
1. Data guaranteed by design, not tested in production.  
2. tWU(WFI) = 2 x 1/fmaster + 7 x 1/fCPU  
3. Measured from interrupt event to interrupt vector fetch.  
4. Configured by the REGAH bit in the CLK_ICKR register.  
5. Configured by the AHALT bit in the FLASH_CR1 register.  
6. Plus 1 LSI clock depending on synchronization.  
62/103  
Doc ID 14733 Rev 9