STM8S207xx, STM8S208xx
Electrical characteristics
Total current consumption in active halt mode
Table 24. Total current consumption in active halt mode at V = 5 V, T -40 to 85° C
DD
A
Conditions
Max(1) Unit
Mainvoltage
regulator
(MVR)(2)
Symbol
Parameter
Typ
Flash mode(3)
Clock source
HSE crystal oscillator
(16 MHz)
1000
200
940
140
Operating mode
LSI RC oscillator
(128 kHz)
260
On
HSE crystal oscillator
(16 MHz)
Supply current in
active halt mode
IDD(AH)
µA
Powerdown mode
LSI RC oscillator
(128 kHz)
Operating mode
68
11
LSI RC oscillator
128 kHz)
Off
Powerdown mode
45
1. Data based on characterization results, not tested in production.
2. Configured by the REGAH bit in the CLK_ICKR register.
3. Configured by the AHALT bit in the FLASH_CR1 register.
Table 25. Total current consumption in active halt mode at V = 3.3 V
DD
Conditions
Typ(1) Unit
Main voltage
Symbol
Parameter
regulator
Flash mode(3)
Clock source
(MVR)(2)
HSE crystal osc. (16 MHz)
LSI RC osc. (128 kHz)
HSE crystal osc. (16 MHz)
LSI RC osc. (128 kHz)
600
200
Operating mode
On
Off
540
µA
140
Supply current in
active halt mode
IDD(AH)
Powerdown mode
Operating mode
66
9
LSI RC osc. (128 kHz)
Powerdown mode
1. Data based on characterization results, not tested in production.
2. Configured by the REGAH bit in the CLK_ICKR register.
3. Configured by the AHALT bit in the FLASH_CR1 register.
Doc ID 14733 Rev 9