 浏览型号STM32F103RET6TR的Datasheet PDF文件第111页浏览型号STM32F103RET6TR的Datasheet PDF文件第112页浏览型号STM32F103RET6TR的Datasheet PDF文件第113页浏览型号STM32F103RET6TR的Datasheet PDF文件第114页浏览型号STM32F103RET6TR的Datasheet PDF文件第116页浏览型号STM32F103RET6TR的Datasheet PDF文件第117页浏览型号STM32F103RET6TR的Datasheet PDF文件第118页浏览型号STM32F103RET6TR的Datasheet PDF文件第119页  
STM32F103xC, STM32F103xD, STM32F103xE  
Package characteristics  
6.2.2  
Selecting the product temperature range  
When ordering the microcontroller, the temperature range is specified in the ordering  
information scheme shown in Table 71: Ordering information scheme.  
Each temperature range suffix corresponds to a specific guaranteed ambient temperature at  
maximum dissipation and, to a specific maximum junction temperature.  
As applications do not commonly use the STM32F103xC, STM32F103xD and  
STM32F103xE at maximum dissipation, it is useful to calculate the exact power  
consumption and junction temperature to determine which temperature range will be best  
suited to the application.  
The following examples show how to calculate the temperature range needed for a given  
application.  
Example 1: High-performance application  
Assuming the following application conditions:  
Maximum ambient temperature T  
= 82 °C (measured according to JESD51-2),  
Amax  
I
= 50 mA, V = 3.5 V, maximum 20 I/Os used at the same time in output at low  
DDmax  
DD  
level with I = 8 mA, V = 0.4 V and maximum 8 I/Os used at the same time in output  
OL  
OL  
at low level with I = 20 mA, V = 1.3 V  
OL  
OL  
P
P
= 50 mA × 3.5 V= 175 mW  
INTmax  
= 20 × 8 mA × 0.4 V + 8 × 20 mA × 1.3 V = 272 mW  
IOmax  
This gives: P  
= 175 mW and P  
= 272 mW:  
IOmax  
INTmax  
P
= 175 + 272 = 447 mW  
Dmax  
Thus: P  
= 447 mW  
Dmax  
Using the values obtained in Table 70 T  
is calculated as follows:  
Jmax  
T
For LQFP100, 46 °C/W  
= 82 °C + (46 °C/W × 447 mW) = 82 °C + 20.6 °C = 102.6 °C  
Jmax  
This is within the range of the suffix 6 version parts (–40 < T < 105 °C).  
J
In this case, parts must be ordered at least with the temperature range suffix 6 (see  
Table 71: Ordering information scheme).  
Example 2: High-temperature application  
Using the same rules, it is possible to address applications that run at high ambient  
temperatures with a low dissipation, as long as junction temperature T remains within the  
J
specified range.  
Assuming the following application conditions:  
Maximum ambient temperature T  
= 115 °C (measured according to JESD51-2),  
Amax  
I
= 20 mA, V = 3.5 V, maximum 20 I/Os used at the same time in output at low  
DDmax  
DD  
level with I = 8 mA, V = 0.4 V  
OL  
OL  
P
P
= 20 mA × 3.5 V= 70 mW  
INTmax  
= 20 × 8 mA × 0.4 V = 64 mW  
IOmax  
This gives: P  
= 70 mW and P  
= 64 mW:  
IOmax  
INTmax  
P
= 70 + 64 = 134 mW  
Dmax  
Thus: P  
= 134 mW  
Dmax  
Doc ID 14611 Rev 7  