 浏览型号STM32F103R4H7XXXTR的Datasheet PDF文件第51页浏览型号STM32F103R4H7XXXTR的Datasheet PDF文件第52页浏览型号STM32F103R4H7XXXTR的Datasheet PDF文件第53页浏览型号STM32F103R4H7XXXTR的Datasheet PDF文件第54页浏览型号STM32F103R4H7XXXTR的Datasheet PDF文件第56页浏览型号STM32F103R4H7XXXTR的Datasheet PDF文件第57页浏览型号STM32F103R4H7XXXTR的Datasheet PDF文件第58页浏览型号STM32F103R4H7XXXTR的Datasheet PDF文件第59页  
STM32F103x4, STM32F103x6  
Electrical characteristics  
5.3.12  
I/O current injection characteristics  
As a general rule, current injection to the I/O pins, due to external voltage below V or  
SS  
above V (for standard, 3 V-capable I/O pins) should be avoided during normal product  
DD  
operation. However, in order to give an indication of the robustness of the microcontroller in  
cases when abnormal injection accidentally happens, susceptibility tests are performed on a  
sample basis during device characterization.  
Functional susceptibilty to I/O current injection  
While a simple application is executed on the device, the device is stressed by injecting  
current into the I/O pins programmed in floating input mode. While current is injected into the  
I/O pin, one at a time, the device is checked for functional failures.  
The failure is indicated by an out of range parameter: ADC error above a certain limit (>5  
LSB TUE), out of spec current injection on adjacent pins or other functional failure (for  
example reset, oscillator frequency deviation).  
The test results are given in Table 34  
Table 34. I/O current injection susceptibility  
Functional susceptibility  
Symbol  
Description  
Unit  
Negative  
injection  
Positive  
injection  
Injected current on OSC_IN32,  
OSC_OUT32, PA4, PA5, PC13  
-0  
+0  
IINJ  
mA  
Injected current on all FT pins  
Injected current on any other pin  
-5  
-5  
+0  
+5  
Doc ID 15060 Rev 5  
55/87  
 
 