STM32F103xx
Electrical characteristics
Typical current consumption
The MCU is placed under the following conditions:
■
■
■
All I/O pins are in input mode with a static value at V or V (no load).
DD SS
All peripherals are disabled except if it is explicitly mentioned.
The Flash access time is adjusted to f frequency (0 wait state from 0 to 24 MHz, 1
HCLK
wait state from 24 to 48 MHZ and 2 wait states above).
■
Ambient temperature and V supply voltage conditions summarized in Table 7.
DD
(1)
Table 13. Typical current consumption in Run and Sleep modes
Symbol Parameter
Conditions
fHCLK
Typ(2)
Unit
72 MHz
48 MHz
36 MHz
24 MHz
16 MHz
8 MHz
21
18
Oscillator running at 8 MHz with PLL, code
running from Flash, all peripheral disabled
TBD
13
mA
(see RCC register description): fPCLK1
fHCLK/2, fPCLK2=fHCLK
=
TBD
7.8
4 MHz
7
Running on HSI clock, code running from
Flash, all peripheral disabled (see RCC
register description): fPCLK1= fHCLK/2,
fPCLK2=fHCLK. AHB pre-scaler used to
reduce the frequency
2 MHz
6.3
Supply
current in
Run mode
mA
1 MHz
6.2
500 kHz
125 kHz
8 MHz
6.1
5.95
2.3
4 MHz
1.6
Running on HSI clock, code running from
RAM, all peripheral disabled (see RCC
register description): fPCLK1= fHCLK/2,
fPCLK2=fHCLK. AHB pre-scaler used to
reduce the frequency
IDD
2 MHz
1.2
mA
mA
1 MHz
1
500 kHz
125 kHz
72 MHz
48 MHz
36 MHz
24 MHz
16 MHz
8 MHz
0.88
0.82
6
TBD
TBD
TBD
1
Oscillator running at 8MHz with PLL, code
running from Flash, all peripheral disabled
(see RCC register description): fPCLK1
HCLK/2, fPCLK2=fHCLK
=
f
Supply
current in
Sleep mode
TBD
TBD
TBD
TBD
TBD
Running on HSI clock, code running from
Flash, all peripheral disabled (see RCC
register description): fPCLK1= fHCLK/2,
fPCLK2=fHCLK. AHB pre-scaler used to
reduce the frequency
4 MHz
2 MHz
mA
1 MHz
500 kHz
1. TBD stands for to be determined.
2. Typical values are measures at TA = 25 °C, VDD = 3.3 V.
31/67