M93C86, M93C76, M93C66, M93C56, M93C46
DC and AC parameters
11
DC and AC parameters
This section summarizes the operating and measurement conditions, and the dc and ac
characteristics of the device. The parameters in the dc and ac characteristic tables that
follow are derived from tests performed under the measurement conditions summarized in
the relevant tables. Designers should check that the operating conditions in their circuit
match the measurement conditions when relying on the quoted parameters.
Table 9.
Symbol
Operating conditions (M93Cx6)
Parameter
Min.
Max.
Unit
VCC
TA
Supply voltage
4.5
–40
–40
5.5
85
V
Ambient operating temperature (device grade 6)
Ambient operating temperature (device grade 3)
°C
°C
125
Table 10. Operating conditions (M93Cx6-W)
Symbol
Parameter
Min.
Max.
Unit
VCC
Supply voltage
2.5
–40
–40
5.5
85
V
Ambient operating temperature (device grade 6)
Ambient operating temperature (device grade 3)
°C
°C
TA
125
Table 11. Operating conditions (M93Cx6-R)
Symbol
Parameter
Min.
Max.
Unit
VCC
TA
Supply voltage
Ambient operating temperature (device grade 6)
1.8
5.5
85
V
–40
°C
(1)
Table 12. AC measurement conditions (M93Cx6)
Symbol
Parameter
Min.
Max.
Unit
CL
Load capacitance
100
pF
ns
V
Input rise and fall times
50
Input pulse voltages
0.4 V to 2.4 V
1.0 V and 2.0 V
0.8 V and 2.0 V
Input timing reference voltages
Output timing reference voltages
V
V
1. Output Hi-Z is defined as the point where data out is no longer driven.
21/38