M24128-BW, M24128-BR, M24256-BW, M24256-BR
DC AND AC PARAMETERS
This section summarizes the operating and mea-
surement conditions, and the DC and AC charac-
teristics of the device. The parameters in the DC
and AC Characteristic tables that follow are de-
rived from tests performed under the Measure-
ment Conditions summarized in the relevant
tables. Designers should check that the operating
conditions in their circuit match the measurement
conditions when relying on the quoted parame-
ters.
Table 8. Operating Conditions (M24128-BW, M24256-BW)
Symbol
V
CC
T
A
Supply Voltage
Ambient Operating Temperature
Parameter
Min.
2.5
–40
Max.
5.5
85
Unit
V
°C
Table 9. Operating Conditions (M24128-BR, M24256-BR)
Symbol
V
CC
T
A
Supply Voltage
Ambient Operating Temperature
Parameter
Min.
1.8
–40
Max.
5.5
85
Unit
V
°C
Table 10. AC Measurement Conditions
Symbol
C
L
Load Capacitance
Input Rise and Fall Times
Input Levels
Input and Output Timing Reference Levels
Parameter
Min.
100
50
0.2V
CC
to 0.8V
CC
0.3V
CC
to 0.7V
CC
Max.
Unit
pF
ns
V
V
Figure 10. AC Measurement I/O Waveform
Input Levels
0.8VCC
Input and Output
Timing Reference Levels
0.7VCC
0.3VCC
AI00825B
0.2VCC
14/25