Electrical characteristics
LM119-LM219-LM319
3
Table 3.
Symbol
Electrical characteristics
VCC = ±15V, Tamb = +25°C (unless otherwise specified)
LM119 - LM219
Parameter
Min.
V
io
I
io
I
ib
A
vd
I
CC
+
LM319
Unit
Min
Typ.
2
80
250
8
40
8
4.3
3
±12
1
±13
3
12.5
5
Max.
8
10
200
300
1000
1200
mV
nA
nA
V/mV
mA
mA
V
Typ.
0.7
30
150
Max.
4
7
75
100
500
1000
Input offset voltage (R
s
≤
5kΩ)
(1) (2)
T
min
≤
T
amb
≤
T
max
Input offset current
T
min
≤
T
amb
≤
T
max
Input bias current
T
min
≤
T
amb
≤
T
max
Large signal voltage gain
Positive supply current
V
CC
= ±15V
V
CC
+
= +5V, V
CC
-
= 0V
Negative supply current
Input common mode voltage range
V
CC
= ±15V
V
CC
+
= +5V, V
CC
-
= 0V
Low level output voltage
I
o
= 25mA
V
i
≤
-5mV
V
i
≤
-10mV
T
min
≤
T
amb
≤
T
max
V
CC+
≥
+4.5V, V
CC-
= 0V, I
o(sink)
< 3.2mA
V
i
≤
-6mV
V
i
≤
-10mV
High level output current (V
o
= +35V)
V
i
≥
5mV
V
i
≥
10mV
T
min
≤
T
amb
≤
T
max
, V
i
≥
5mV
Response time
(3)
±12
1
10
40
8
4.3
3
±13
3
11.5
4.5
I
CC
-
V
icm
0.75
1.5
0.75
1.5
V
V
OL
0.23
0.4
0.3
0.4
I
OH
0.2
1
80
2
0.2
10
80
10
μA
t
res
ns
1. These specifications apply for V
CC
= ±15V, unless otherwise stated.The offset voltage, offset current and bias current
specifications apply for any supply voltage from a single +5V up to ±15V supplies. The offset voltages and offset current
given are the maximum values required to drive the output down to 1V or up to +14V with a 1mA load current. Thus, these
parameters define an error band and take into account the worst case effects of voltage gain and input impedance.
2. At output switch point, Vo
≈
1.4V, no load, with V
CC
from 5V to ±15V and over the full input common-mode range.
3. The response time specified is for a 100mV input step with 5mV overdrive.
4/12