LIS3DH
Registers description
Table 56. CLICK_CFG description
Enable interrupt double CLICK-CLICK on Z axis. Default value: 0
ZD
ZS
YD
YS
XD
XS
(0: disable interrupt request; 1: enable interrupt request on measured accel. value
higher than preset threshold)
Enable interrupt single CLICK-CLICK on Z axis. Default value: 0
(0: disable interrupt request; 1: enable interrupt request on measured accel. value
higher than preset threshold)
Enable interrupt double CLICK-CLICK on Y axis. Default value: 0
(0: disable interrupt request; 1: enable interrupt request on measured accel. value
higher than preset threshold)
Enable interrupt single CLICK-CLICK on Y axis. Default value: 0
(0: disable interrupt request; 1: enable interrupt request on measured accel. value
higher than preset threshold)
Enable interrupt double CLICK-CLICK on X axis. Default value: 0
(0: disable interrupt request; 1: enable interrupt request on measured accel. value
higher than preset threshold)
Enable interrupt single CLICK-CLICK on X axis. Default value: 0
(0: disable interrupt request; 1: enable interrupt request on measured accel. value
higher than preset threshold)
8.26
CLICK_SRC (39h)
Table 57. CLICK_SRC register
IA
DCLICK
SCLICK
Sign
Z
Y
X
Table 58. CLICK_SRC description
-
-
IA
Interrupt active. Default value: 0
(0: no interrupt has been generated; 1: one or more interrupts have been generated)
DCLICK
SCLICK
Double CLICK-CLICK enable. Default value: 0 (0:double CLICK-CLICK detection dis-
able, 1: double CLICK-CLICK detection enable)
Single CLICK-CLICK enable. Default value: 0 (0:Single CLICK-CLICK detection dis-
able, 1: single CLICK-CLICK detection enable)
Sign
Z
CLICK-CLICK Sign. 0: positive detection, 1: negative detection
Z CLICK-CLICK detection. Default value: 0
(0: no interrupt, 1: Z High event has occurred)
Y
X
Y CLICK-CLICK detection. Default value: 0
(0: no interrupt, 1: Y High event has occurred)
X CLICK-CLICK detection. Default value: 0
(0: no interrupt, 1: X High event has occurred)
Doc ID 17530 Rev 1