M54/M74HC192/193
ABSOLUTE MAXIMUM RATINGS
Symbol
VCC
VI
Parameter
Value
-0.5 to +7
-0.5 to VCC + 0.5
-0.5 to VCC + 0.5
± 20
Unit
V
Supply Voltage
DC Input Voltage
V
VO
DC Output Voltage
V
IIK
DC Input Diode Current
DC Output Diode Current
DC Output Source Sink Current Per Output Pin
mA
mA
mA
mA
mW
oC
IOK
± 20
IO
± 25
ICC or IGND DC VCC or Ground Current
± 50
PD
Tstg
TL
Power Dissipation
500 (*)
Storage Temperature
Lead Temperature (10 sec)
-65 to +150
300
oC
Absolute MaximumRatingsare those values beyond whichdamage tothe device may occur. Functional operation under these condition isnotimplied.
(*) 500 mW: 65 oC derate to 300 mW by 10mW/oC: 65 oC to 85 oC
RECOMMENDED OPERATING CONDITIONS
Symbol
VCC
VI
Parameter
Value
2 to 6
Unit
V
Supply Voltage
Input Voltage
Output Voltage
0 to VCC
0 to VCC
V
VO
V
Top
Operating Temperature: M54HC Series
M74HC Series
-55 to +125
-40 to +85
oC
oC
tr, tf
Input Rise and Fall Time
VCC = 2 V
VCC = 4.5 V
VCC = 6 V
0 to 1000
0 to 500
0 to 400
ns
6/15