欢迎访问ic37.com |
会员登录 免费注册
发布采购

S29GL128P90FFI012 参数 Datasheet PDF下载

S29GL128P90FFI012图片预览
型号: S29GL128P90FFI012
PDF下载: 下载PDF文件 查看货源
内容描述: 3.0伏只页面模式闪存具有90纳米的MirrorBit工艺技术 [3.0 Volt-only Page Mode Flash Memory featuring 90 nm MirrorBit Process Technology]
分类和应用: 闪存
文件页数/大小: 77 页 / 2742 K
品牌: SPANSION [ SPANSION ]
 浏览型号S29GL128P90FFI012的Datasheet PDF文件第42页浏览型号S29GL128P90FFI012的Datasheet PDF文件第43页浏览型号S29GL128P90FFI012的Datasheet PDF文件第44页浏览型号S29GL128P90FFI012的Datasheet PDF文件第45页浏览型号S29GL128P90FFI012的Datasheet PDF文件第47页浏览型号S29GL128P90FFI012的Datasheet PDF文件第48页浏览型号S29GL128P90FFI012的Datasheet PDF文件第49页浏览型号S29GL128P90FFI012的Datasheet PDF文件第50页  
Data
Sheet
(Pre limin ar y)
5. There is no means to verify what the password is after it is set.
6. The Password Mode Lock Bit, once set, prevents reading the 64-bit password on the data bus and
further password programming.
7. The Password Mode Lock Bit is not erasable.
8. The lower two address bits (A1–A0) are valid during the Password Read, Password Program, and
Password Unlock.
9. The exact password must be entered in order for the unlocking function to occur.
10. The Password Unlock command cannot be issued any faster than 1 µs at a time to prevent a
hacker from running through all the 64-bit combinations in an attempt to correctly match a
password.
11. Approximately 1 µs is required for unlocking the device after the valid 64-bit password is given to
the device.
12. Password verification is only allowed during the password programming operation.
13. All further commands to the password region are disabled and all operations are ignored.
14. If the password is lost after setting the Password Mode Lock Bit, there is no way to clear the PPB
Lock Bit.
15. Entry command sequence must be issued prior to any of any operation and it disables reads and
writes for Sector 0. Reads and writes for other sectors excluding Sector 0 are allowed.
16. If the user attempts to program or erase a protected sector, the device ignores the command and
returns to read mode.
17. A program or erase command to a protected sector enables status polling and returns to read
mode without having modified the contents of the protected sector.
18. The programming of the DYB, PPB, and PPB Lock for a given sector can be verified by writing
individual status read commands DYB Status, PPB Status, and PPB Lock Status to the device.
46
S29GL-P MirrorBit
®
Flash Family
S29GL-P_00_A7 November 8, 2007