欢迎访问ic37.com |
会员登录 免费注册
发布采购

MBM29F800BA-90PF 参数 Datasheet PDF下载

MBM29F800BA-90PF图片预览
型号: MBM29F800BA-90PF
PDF下载: 下载PDF文件 查看货源
内容描述: FL灰内存 [FLASH MEMORY]
分类和应用: 闪存存储内存集成电路光电二极管
文件页数/大小: 49 页 / 569 K
品牌: SPANSION [ SPANSION ]
 浏览型号MBM29F800BA-90PF的Datasheet PDF文件第12页浏览型号MBM29F800BA-90PF的Datasheet PDF文件第13页浏览型号MBM29F800BA-90PF的Datasheet PDF文件第14页浏览型号MBM29F800BA-90PF的Datasheet PDF文件第15页浏览型号MBM29F800BA-90PF的Datasheet PDF文件第17页浏览型号MBM29F800BA-90PF的Datasheet PDF文件第18页浏览型号MBM29F800BA-90PF的Datasheet PDF文件第19页浏览型号MBM29F800BA-90PF的Datasheet PDF文件第20页  
MBM29F800TA-55/-70/-90/MBM29F800BA-55/-70/-90  
COMMAND DEFINITIONS  
Device operations are selected by writing specific address and data sequences into the command register.  
Writing incorrect address and data values or writing them in the improper sequence will reset the device to the  
readmode. “MBM29F800TA/BACommandDefinitionsin DEVICEBUSOPERATIONdefinesthevalidregister  
command sequences. Note that the Erase Suspend (B0h) and Erase Resume (30h) commands are valid only  
while the Sector Erase operation is in progress. Moreover both Read/Reset commands are functionally  
equivalent, resetting the device to the read mode. Please note that commands are always written at DQ7 to DQ0  
and DQ15 to DQ8 bits are ignored.  
Read/Reset Command  
The read or eset operation is initiated by writing the Read/Reset command sequence into the command register.  
Microprocessor read cycles retrieve array data from the memory. The devices remain enabled for reads until the  
command register contents are altered.  
The device will automatically power-up in the read/reset state. In this case, a command sequence is not required  
to read data. Standard microprocessor read cycles will retrieve array data. This default value ensures that no  
spurious alteration of the memory content occurs during the power transition.  
Refer to “AC CHARACTERISTICS” and “TIMING DIAGRAM” for the specific timing parameters.  
Autoselect Command  
Flash memories are intended for use in applications where the local CPU alters memory contents. As such,  
manufacture and device codes must be accessible while the devices reside in the target system. PROM  
programmers typically access the signature codes by raising A9 to a high voltage. However, multiplexing high  
voltage onto the address lines is not generally desired system design practice.  
The device contains an Autoselect command operation to supplement traditional PROM programming  
methodology. The operation is initiated by writing the Autoselect command sequence into the command register.  
Following the command write, a read cycle from address XX00h retrieves the manufacture code of 04h. A read  
cycle from address XX01h for ×16 (XX02h for ×8) returns the device code (MBM29F800TA = D6h and  
MBM29F800BA = 58h for ×8 mode; MBM29F800TA = 22D6h and MBM29F800BA = 2258h for ×16 mode). (See  
“MBM29F800TA/BA Sector Protection Verify Autoselect Codes” and “Expanded Autoselect Code Table” in  
DEVICE BUS OPERATION.)  
All manufacturer and device codes will exhibit odd parity with DQ7 defined as the parity bit.  
Sector state (protection or unprotection) will be informed by address XX02h for ×16 (XX04h for ×8).  
Scanning the sector addresses (A18, A17, A16, A15, A14, A13, and A12) while (A6, A1, A0) = (0, 1, 0) will produce a  
logical “1” at device output DQ0 for a protected sector. The programming verification should be perform margin  
mode on the protected sector (See “MBM29F800TA/BA User Bus Operation (BYTE = VIH)” and “MBM29F800TA/  
BA User Bus Operation (BYTE = VIH)” in DEVICE BUS OPERATION).  
To terminate the operation, it is necessary to write the Read/Reset command sequence into the register, and  
also to write the Autoselect command during the operation, execute it after writing Read/Reset command  
sequence.  
Byte/Word Programming  
The device is programmed on a byte-by-byte (or word-by-word) basis. Programming is a four bus cycle operation.  
There are two “unlock” write cycles. These are followed by the program set-up command and data write cycles.  
Addresses are latched on the falling edge of CE or WE, whichever happens later and the data is latched on the  
rising edge of CE or WE, whichever happens first. The rising edge of CE or WE (whichever happens first) begins  
programming. Upon executing the Embedded ProgramTM Algorithm command sequence, the system is not  
requiredtoprovidefurthercontrolsortimings.Thedevicewillautomaticallyprovideadequateinternallygenerated  
program pulses and verify the programmed cell margin.  
The automatic programming operation is completed when the data on DQ7 is equivalent to data written to this  
bit at which time the devices return to the read mode and addresses are no longer latched (See “Hardware  
Sequence Flags”, Hardware Sequence Flags) Therefore, the devices require that a valid address to the devices  
15  
 复制成功!