 浏览型号MBM29F800BA-90PF的Datasheet PDF文件第11页浏览型号MBM29F800BA-90PF的Datasheet PDF文件第12页浏览型号MBM29F800BA-90PF的Datasheet PDF文件第13页浏览型号MBM29F800BA-90PF的Datasheet PDF文件第14页浏览型号MBM29F800BA-90PF的Datasheet PDF文件第16页浏览型号MBM29F800BA-90PF的Datasheet PDF文件第17页浏览型号MBM29F800BA-90PF的Datasheet PDF文件第18页浏览型号MBM29F800BA-90PF的Datasheet PDF文件第19页  
MBM29F800TA-55/-70/-90/MBM29F800BA-55/-70/-90  
Write  
Device erasure and programming are accomplished via the command register. The contents of the register serve  
as inputs to the internal state machine. The state machine outputs dictate the function of the device.  
The command register itself does not occupy any addressable memory location. The register is a latch used to  
store the commands, along with the address and data information needed to execute the command. The  
command register is written by bringing WE to VIL, while CE is at VIL and OE is at VIH. Addresses are latched on  
the falling edge of WE or CE, whichever happens later; while data is latched on the rising edge of WE or CE,  
whichever happens first. Standard microprocessor write timings are used.  
Refer to “AC CHARACTERISTICDS” and “TIMING DIAGRAM” for specific timing parameters.  
Sector Protection  
The MBM29F800TA/BA features hardware sector protection. This feature will disable both program and erase  
operations in any number of sectors (0 through 18). The sector protection feature is enabled using programming  
equipment at the user’s site. The device is shipped with all sectors unprotected.  
To activate this mode, the programming equipment must force VID on address pin A9 and control pin OE, (suggest  
VID = 11.5V), CE = VIL, and A6 = VIL. The sector addresses (A18, A17, A16, A15, A14, A13, and A12) should be set to  
the sector to be protected. “Sector Address Tables (MBM29F800TA)” and “Sector Address Tables  
(MBM29F800BA)” in FLEXIBLE SECTOR ERASE ARCHITECTURE define the sector address for each of  
the nineteen (19) individual sectors. Programming of the protection circuitry begins on the falling edge of the  
WE pulse and is terminated with the rising edge of the same. Sector addresses must be held constant during  
theWEpulse. SeeSectorProtection TimingDiagramin TIMINGDIAGRAMandSectorProtectionAlgorithm”  
in FLOW CHART for sector protection waveforms and algorithm.  
To verify programming of the protection circuitry, the programming equipment must force VID on address pin A9  
with CE and OE at VIL and WE at VIH. Scanning the sector addresses (A18, A17, A16, A15, A14, A13, and A12) while  
(A6, A1, A0) = (0, 1, 0) will produce a logical “1” code at device output DQ0 for a protected sector. Otherwise the  
devices will read 00h for unprotected sector. In this mode, the lower order addresses, except for A0, A1, and A6  
are DON’T CARES. Address locations with A1 = VIL are reserved for Autoselect manufacturer and device codes.  
A-1 requires to apply to VIL on byte mode.  
ItisalsopossibletodetermineifasectorisprotectedinthesystembywritinganAutoselectcommand. Performing  
a read operation at the address location XX02h, where the higher order addresses (A18, A17, A16, A15, A14, A13,  
and A12) are the desired sector address will produce a logical “1” at DQ0 for a protected sector. See  
“MBM29F800TA/BA Sector Protection Verify Autoselect Codes” and “Expanded Autoselect Code Table” in  
DEVICE BUS OPERATION for Autoselect codes.  
Temporary Sector Unprotection  
This feature allows temporary unprotection of previously protected sectors of the MBM29F800TA/BA device in  
order to change data. The Sector Unprotection mode is activated by setting the RESET pin to high voltage  
(12 V). During this mode, formerly protected sectors can be programmed or erased by selecting the sector  
addresses. Once the 12 V is taken away from the RESETpin, all the previously protected sectors will be protected  
again. Refer to “Temporary Sector Unprotection Timing Diagram” in TIMING DIAGRAM and “Temporary Sector  
Unprotection Algorithm” in FLOW CHART.  