 浏览型号AM29DL162CT-120ZF的Datasheet PDF文件第18页浏览型号AM29DL162CT-120ZF的Datasheet PDF文件第19页浏览型号AM29DL162CT-120ZF的Datasheet PDF文件第20页浏览型号AM29DL162CT-120ZF的Datasheet PDF文件第21页浏览型号AM29DL162CT-120ZF的Datasheet PDF文件第23页浏览型号AM29DL162CT-120ZF的Datasheet PDF文件第24页浏览型号AM29DL162CT-120ZF的Datasheet PDF文件第25页浏览型号AM29DL162CT-120ZF的Datasheet PDF文件第26页  
P R E L I M I N A R Y  
DQ6 status bits to indicate the operation was success-  
Enter SecSi Sector/Exit SecSi Sector  
Command Sequence  
ful. However, a succeeding read will show that the  
data is still “0.” Only erase operations can convert a “0”  
to a “1.”  
The system can access the SecSi Sector region by is-  
suing the three-cycle Enter SecSi Sector command  
sequence. The device continues to access the SecSi  
Sector region until the system issues the four-cycle  
Exit SecSi Sector command sequence. The Exit SecSi  
Sector command sequence returns the device to nor-  
mal operation. Table 14 shows the address and data  
requirements for both command sequences. See also  
“SecSi (Secured Silicon) Sector Flash Memory Re-  
gion” for further information. Note that a hardware  
reset (RESET#=VIL) will reset the device to reading  
array data.  
Unlock Bypass Command Sequence  
The unlock bypass feature allows the system to pro-  
gram bytes or words to a bank faster than using the  
standard program command sequence. The unlock  
bypass command sequence is initiated by first writing  
two unlock cycles. This is followed by a third write  
cycle containing the unlock bypass command, 20h.  
That bank then enters the unlock bypass mode. A  
two-cycle unlock bypass program command sequence  
is all that is required to program in this mode. The first  
cycle in this sequence contains the unlock bypass pro-  
gram command, A0h; the second cycle contains the  
program address and data. Additional data is pro-  
grammed in the same manner. This mode dispenses  
with the initial two unlock cycles required in the stan-  
dard program command sequence, resulting in faster  
total programming time. Table 14 shows the require-  
ments for the command sequence.  
Byte/Word Program Command Sequence  
The system may program the device by word or byte,  
depending on the state of the BYTE# pin. Program-  
ming is a four-bus-cycle operation. The program  
command sequence is initiated by writing two unlock  
write cycles, followed by the program set-up com-  
mand. The program address and data are written next,  
which in turn initiate the Embedded Program algo-  
rithm. The system is not required to provide further  
controls or timings. The device automatically provides  
internally generated program pulses and verifies the  
programmed cell margin. Table 14 shows the address  
and data requirements for the byte program command  
sequence.  
During the unlock bypass mode, only the Unlock By-  
pass Program and Unlock Bypass Reset commands  
are valid. To exit the unlock bypass mode, the system  
must issue the two-cycle unlock bypass reset com-  
mand sequence. The first cycle must contain the bank  
address and the data 90h. The second cycle need  
only contain the data 00h. The bank then returns to  
the reading array data.  
When the Embedded Program algorithm is complete,  
that bank then returns to reading array data and ad-  
dresses are no longer latched. The system can  
determine the status of the program operation by  
using DQ7, DQ6, or RY/BY#. Refer to the Write Oper-  
ation Status section for information on these status  
bits.  
The device offers accelerated program operations  
through the WP#/ACC pin. When the system asserts  
on the WP#/ACC pin, the device automatically en-  
VHH  
ters the Unlock Bypass mode. The system may then  
write the two-cycle Unlock Bypass program command  
sequence. The device uses the higher voltage on the  
WP#/ACC pin to accelerate the operation. Note that  
the WP#/ACC pin must not be at VHH any operation  
other than accelerated programming, or device dam-  
age may result. In addition, the WP#/ACC pin must not  
be left floating or unconnected; inconsistent behavior  
of the device may result.  
Any commands written to the device during the Em-  
bedded Program Algorithm are ignored. Note that a  
hardware reset immediately terminates the program  
operation. The program command sequence should  
be reinitiated once that bank has returned to reading  
array data, to ensure data integrity.  
Programming is allowed in any sequence and across  
sector boundaries. A bit cannot be programmed  
from “0” back to a “1.” Attempting to do so may  
cause that bank to set DQ5 = 1, or cause the DQ7 and  
Figure 3 illustrates the algorithm for the program oper-  
ation. Refer to the Erase and Program Operations  
table in the AC Characteristics section for parameters,  
and Figure 17 for timing diagrams.  
Am29DL162C/Am29DL163C  
22  