 浏览型号AM29BL802C70RZI的Datasheet PDF文件第20页浏览型号AM29BL802C70RZI的Datasheet PDF文件第21页浏览型号AM29BL802C70RZI的Datasheet PDF文件第22页浏览型号AM29BL802C70RZI的Datasheet PDF文件第23页浏览型号AM29BL802C70RZI的Datasheet PDF文件第25页浏览型号AM29BL802C70RZI的Datasheet PDF文件第26页浏览型号AM29BL802C70RZI的Datasheet PDF文件第27页浏览型号AM29BL802C70RZI的Datasheet PDF文件第28页  
D A T A S H E E T  
Table 5 shows the outputs for Toggle Bit I on DQ6. Fig-  
RY/BY#: Ready/Busy#  
ure 8 shows the toggle bit algorithm in flowchart form,  
and the section “Reading Toggle Bits DQ6/DQ2” ex-  
plains the algorithm. Figure 21 in the “AC Characteris-  
tics” section shows the toggle bit timing diagrams.  
Figure 22 shows the differences between DQ2 and  
DQ6 in graphical form. See also the subsection on  
“DQ2: Toggle Bit II”.  
The RY/BY# is a dedicated, open-drain output pin that  
indicates whether an Embedded Algorithm is in  
progress or complete. The RY/BY# status is valid after  
the rising edge of the final WE# pulse in the command  
sequence. Since RY/BY# is an open-drain output, sev-  
eral RY/BY# pins can be tied together in parallel with a  
pull-up resistor to V  
.
CC  
DQ2: Toggle Bit II  
If the output is low (Busy), the device is actively erasing  
or programming. (This includes programming in the  
Erase Suspend mode.) If the output is high (Ready),  
the device is ready to read array data (including during  
the Erase Suspend mode), or is in the standby mode.  
The “Toggle Bit II” on DQ2, when used with DQ6, indi-  
cates whether a particular sector is actively erasing  
(that is, the Embedded Erase algorithm is in progress),  
or whether that sector is erase-suspended. Toggle Bit  
II is valid after the rising edge of the final WE# pulse in  
the command sequence.  
Table 5 shows the outputs for RY/BY#. Figures 15, 17,  
18 and 19 shows RY/BY# for read, reset, program, and  
erase operations, respectively.  
DQ2 toggles when the system reads at addresses  
within those sectors that have been selected for era-  
sure. (The system may use either OE# or CE# to con-  
trol the read cycles.) But DQ2 cannot distinguish  
whether the sector is actively erasing or is erase-sus-  
pended. DQ6, by comparison, indicates whether the  
device is actively erasing, or is in Erase Suspend, but  
cannot distinguish which sectors are selected for era-  
sure. Thus, both status bits are required for sector and  
mode information. Refer to Table 5 to compare outputs  
for DQ2 and DQ6.  
DQ6: Toggle Bit I  
Toggle Bit I on DQ6 indicates whether an Embedded  
Program or Erase algorithm is in progress or complete,  
or whether the device has entered the Erase Suspend  
mode. Toggle Bit I may be read at any address, and is  
valid after the rising edge of the final WE# pulse in the  
command sequence (prior to the program or erase op-  
eration), and during the sector erase time-out.  
During an Embedded Program or Erase algorithm op-  
eration, successive read cycles to any address cause  
DQ6 to toggle. (The system may use either OE# or  
CE# to control the read cycles.) When the operation is  
complete, DQ6 stops toggling.  
Figure 8 shows the toggle bit algorithm in flowchart  
form, and the section “Reading Toggle Bits DQ6/DQ2”  
explains the algorithm. See also the DQ6: Toggle Bit I  
subsection. Figure 21 shows the toggle bit timing dia-  
gram. Figure 22 shows the differences between DQ2  
and DQ6 in graphical form.  
After an erase command sequence is written, if all sec-  
tors selected for erasing are protected, DQ6 toggles for  
approximately 100 µs, then returns to reading array  
data. If not all selected sectors are protected, the Em-  
bedded Erase algorithm erases the unprotected sec-  
tors, and ignores the selected sectors that are protected.  
Reading Toggle Bits DQ6/DQ2  
Refer to Figure 8 for the following discussion. When-  
ever the system initially begins reading toggle bit sta-  
tus, it must read DQ7–DQ0 at least twice in a row to  
determine whether a toggle bit is toggling. Typically,  
the system would note and store the value of the tog-  
gle bit after the first read. After the second read, the  
system would compare the new value of the toggle bit  
with the first. If the toggle bit is not toggling, the device  
has completed the program or erase operation. The  
system can read array data on DQ7–DQ0 on the fol-  
lowing read cycle.  
The system can use DQ6 and DQ2 together to deter-  
mine whether a sector is actively erasing or is erase-  
suspended. When the device is actively erasing (that is,  
the Embedded Erase algorithm is in progress), DQ6  
toggles. When the device enters the Erase Suspend  
mode, DQ6 stops toggling. However, the system must  
also use DQ2 to determine which sectors are erasing  
or erase-suspended. Alternatively, the system can use  
DQ7 (see the subsection on “DQ7: Data# Polling”).  
However, if after the initial two read cycles, the system  
determines that the toggle bit is still toggling, the sys-  
tem also should note whether the value of DQ5 is high  
(see the section on DQ5). If it is, the system should  
then determine again whether the toggle bit is toggling,  
since the toggle bit may have stopped toggling just as  
DQ5 went high. If the toggle bit is no longer toggling,  
the device has successfully completed the program or  
erase operation. If it is still toggling, the device did not  
complete the operation successfully, and the system  
If a program address falls within a protected sector,  
DQ6 toggles for approximately 1 µs after the program  
command sequence is written, then returns to reading  
array data.  
DQ6 also toggles during the erase-suspend-program  
mode, and stops toggling once the Embedded Pro-  
gram algorithm is complete.  
22  