 浏览型号AM29BDD160GB54DPBF的Datasheet PDF文件第29页浏览型号AM29BDD160GB54DPBF的Datasheet PDF文件第30页浏览型号AM29BDD160GB54DPBF的Datasheet PDF文件第31页浏览型号AM29BDD160GB54DPBF的Datasheet PDF文件第32页浏览型号AM29BDD160GB54DPBF的Datasheet PDF文件第34页浏览型号AM29BDD160GB54DPBF的Datasheet PDF文件第35页浏览型号AM29BDD160GB54DPBF的Datasheet PDF文件第36页浏览型号AM29BDD160GB54DPBF的Datasheet PDF文件第37页  
system can read CFI information at the addresses  
given in Tables 13–16. To terminate reading CFI data,  
the system must write the reset command.  
COMMON FLASH MEMORY INTERFACE  
(CFI)  
The Common Flash Interface (CFI) specification out-  
lines device and host system software interrogation  
handshake, which allows specific vendor-specified  
software algorithms to be used for entire families of  
devices. Software support can then be device-inde-  
pendent, JEDEC ID-independent, and forward- and  
backward-compatible for the specified flash device  
families. Flash vendors can standardize their existing  
interfaces for long-term compatibility.  
The system can also write the CFI query command  
when the device is in the autoselect mode. The device  
enters the CFI query mode, and the system can read  
CFI data at the addresses given in Tables 13–16. The  
system must write the reset command to return the de-  
vice to the autoselect mode.  
For further information, please refer to the CFI Specifi-  
cation and CFI Publication 100, available via the  
World Wide Web at http://www.amd.com/prod-  
ucts/nvd/overview/cfi.html. Alternatively, contact an  
AMD representative for copies of these documents.  
This device enters the CFI Query mode when the sys-  
tem writes the CFI Query command, 98h, to address  
55h in word mode (or address AAh in byte mode), any  
time the device is ready to read array data. The  
Table 14. CFI Query Identification String  
Addresses  
(x32 Mode)  
Addresses  
(x16 Mode)  
Data  
Description  
10h  
11h  
12h  
20h  
22h  
24h  
0051h  
0052h  
0059h  
Query Unique ASCII string “QRY”  
13h  
14h  
26h  
28h  
0002h  
0000h  
Primary OEM Command Set  
15h  
16h  
2Ah  
2Ch  
0040h  
0000h  
Address for Primary Extended Table  
17h  
18h  
2Eh  
30h  
0000h  
0000h  
Alternate OEM Command Set (00h = none exists)  
Address for Alternate OEM Extended Table (00h = none exists)  
19h  
1Ah  
32h  
34h  
0000h  
0000h  
Table 15. CFI System Interface String  
Addresses  
(x32 Mode)  
Addresses  
(x16 Mode)  
Data  
Description  
VCC Min. (write/erase)  
DQ7–DQ4: volts, DQ3–DQ0: 100 millivolt  
1Bh  
1Ch  
36h  
38h  
0023h  
VCC Max. (write/erase)  
DQ7–DQ4: volts, DQ3–DQ0: 100 millivolt  
0027h  
1Dh  
1Eh  
1Fh  
20h  
21h  
22h  
23h  
24h  
25h  
26h  
3Ah  
3Ch  
3Eh  
40h  
42h  
44h  
46h  
48h  
4Ah  
4Ch  
0000h  
0000h  
0004h  
0000h  
0009h  
0000h  
0005h  
0000h  
0007h  
0000h  
V
PP Min. voltage (00h = no VPP pin present)  
PP Max. voltage (00h = no VPP pin present)  
V
Typical timeout per single word/doubleword program 2N µs  
Typical timeout for Min. size buffer program 2N µs (00h = not supported)  
Typical timeout per individual block erase 2N ms  
Typical timeout for full chip erase 2N ms (00h = not supported)  
Max. timeout for word/doubleword program 2N times typical  
Max. timeout for buffer write 2N times typical  
Max. timeout per individual block erase 2N times typical  
Max. timeout for full chip erase 2N times typical (00h = not supported)  
June 7, 2006  