CXA2095S  
G-CUTOFF  
B-CUTOFF  
RON  
(4)  
(4)  
(1)  
(1)  
(1)  
(1)  
(1)  
: Gch cut-off adjustment (Gch reference pulse value control of IKIN pin input)  
0H = 62%  
7H = 100%  
FH = 150%  
(G/R: Gch reference pulse amplitude when Rch reference  
pulse amplitude of IKIN pin input is assumed 100%)  
: Bch cut-off adjustment (Bch reference pulse value control of IKIN pin input)  
0H = 62%  
7H = 100%  
FH = 150%  
(B/R: Bch reference pulse amplitude when Rch reference  
pulse amplitude of IKIN pin input is assumed 100%)  
: ON/OFF switch for Rch video output without a reference pulse  
(Operates when PICON = 1, set to OFF mode at power-on.)  
0 = Rch video output OFF (Blanked status, reference pulse only output)  
1 = Rch video output ON  
GON  
: ON/OFF switch for Gch video output without a reference pulse  
(Operates when PICON = 1, set to OFF mode at power-on.)  
0 = Gch video output OFF (Blanked status, reference pulse only output)  
1 = Gch video output ON  
BON  
: ON/OFF switch for Bch video output without a reference pulse  
(Operates when PICON = 1, set to OFF mode at power-on.)  
0 = Bch video output OFF (Blanked status, reference pulse only output)  
1 = Bch video output ON  
PICON  
VOFF  
: ON/OFF switch for RGB output with a reference pulse (Set to OFF mode at  
power-on.)  
0 = RGB output OFF (All blanked status)  
1 = RGB output ON  
: V sawtooth wave oscillation stop ON/OFF switch (Set to OFF mode at  
power-on.)  
0 = Oscillation stop OFF (VDRIVE– and VDRIVE+: normal output)  
1 = Oscillation stop ON (VDRIVE– and VDRIVE+: DC output and DC value  
vary according to V-POSITION.)  
FHHI  
(1)  
(1)  
: H oscillator frequency fixation ON/OFF switch (Set to ON mode at power-on.)  
0 = H oscillator frequency fixation OFF AFC normal mode  
1 = H oscillator frequency fixation ON  
Oscillator frequency fixed to  
maximum value (16.252kHz).  
CD-MODE  
: V countdown system mode selector switch  
(Set to automatic selection mode during power-on.)  
0 = Non-standard signal mode, standard signal mode and no signal mode  
automatically selected  
1 = Fixed to non-standard signal mode  
(V oscillator frequency is 55Hz during no signal mode (free run).)  
– 21 –  