CXA1734S  
Description of Control Registers  
ATT (4):  
Adjust the signal level input to COMPIN (Pin 11) to the reference level (245 mVrms).  
Variable range of the input signal: 245 mVrms –5.0 dB to +3.0 dB  
0 = Level min.  
F = Level max.  
STVCO (6):  
SAPVCO (4):  
SAPLPF (4):  
STLPF (6):  
Adjust STEREO VCO free running frequency (f0).  
Variable range:  
f0 ±20%  
0 = Free running frequency min.  
3F = Free running frequency max.  
Adjust SAPVCO free running frequency (f0).  
Variable range:  
f0 ±20%  
0 = Free running frequency min.  
F = Free running frequency max.  
Adjust the filter f0 of the SAP block.  
Variable range:  
f0 ±20%  
0 = Frequency min.  
F = Frequency max.  
Adjust the filter f0 of the ST and dbx blocks.  
Variable range:  
f0 ±20%  
0 = Frequency min.  
3F = Frequency max.  
SPECTRAL (6): Perform high frequency (fs = 3 kHz) separation adjustment.  
0 = Level max.  
3F = Level min.  
WIDEBAND (6): Perform low frequency (fs = 300 Hz) separation adjustment.  
0 = Level min.  
3F = Level max.  
TEST1 (1):  
Set filter adjustment mode.  
0 = Normal mode  
1 = STLPF (STA3) and SAPLPF (STA4) adjustment mode  
In addition, the following outputs are present at Pins 28 and 29.  
LOUT (Pin 29):  
ROUT (Pin 28):  
SAP BPF OUT  
NR BPF OUT  
TEST-DA (1):  
Set DAC output test mode and STVCO adjustment mode.  
0 = Normal mode  
1 = DAC output test mode and STVCO adjustment mode  
LOUT (Pin 29):  
ROUT (Pin 28):  
DA control DC level  
STEREO VCO oscillation frequency (4 fH)  
—21—  