 浏览型号USB3813I-1080XY的Datasheet PDF文件第32页浏览型号USB3813I-1080XY的Datasheet PDF文件第33页浏览型号USB3813I-1080XY的Datasheet PDF文件第34页浏览型号USB3813I-1080XY的Datasheet PDF文件第35页浏览型号USB3813I-1080XY的Datasheet PDF文件第37页浏览型号USB3813I-1080XY的Datasheet PDF文件第38页浏览型号USB3813I-1080XY的Datasheet PDF文件第39页浏览型号USB3813I-1080XY的Datasheet PDF文件第40页  
USB 2.0 Hi-Speed 3-Port Hub Controller Optimized for Portable Applications  
Datasheet  
Table 7.1 SMBus Accessible Run Time Registers (continued)  
XDATA  
ADDR  
NAME  
BC_CTL_RUN_TIME  
(Upstream)  
0x6102  
0x6103  
Table 7.16, "Upstream (Port 0) Battery Charging Run Time Control  
Register"  
BC_CTL_DET  
(Upstream)  
Table 7.17, "Upstream (Port 0) Battery Charging Detect Register"  
Table 7.2 Upstream Battery Charging Detection Control Register  
UPSTREAM BATTERY CHARGING REGISTER  
UP_BC_DET  
(0x30E2 - RESET= 0x02)  
BIT  
NAME  
R/W  
DESCRIPTION  
7:5  
CHARGER_TYPE  
R/W  
Read Only.  
This field indicates the result of the automatic charger detection. Values  
reported depend on EnhancedChrgDet bit setting in Upstream Battery  
Charger Mode Register.  
If EnhancedChrgDet = 1  
000 = Charger Detection is not complete.  
001 = DCP - Dedicated Charger Port  
010 = CDP – Charging Downstream Port  
011 = SDP – Standard Downstream Port  
100 = Apple Low Current Charger  
101 = Apple High Current Charger  
110 = Apple Super High Current Charger  
111 = Charger Detection Disabled  
If EnhancedChrgDet = 0  
000 = Charger Detection is not complete.  
001 = DCP/CDP – Dedicated Charger or Charging Downstream Port  
010 = Reserved  
011 = SDP – Standard Downstream Port  
100 = Apple Low Current Charger  
101 = Apple High Current Charger  
110 = Apple Super High Current Charger  
111 = Charger Detection Disabled  
4
CHGDET_COMPLETE  
R
Indicates Charger Detection has been run and is completed. This bit is  
negated when START_CHG_DET is asserted high.  
3
Reserved  
R/W  
R
Reserved for debugging  
2:1  
CHG_DET[1:0]  
Indicates encoded status of what chargers or status has been detected  
according to the settings in the Charge Detect Mask Register. It can be  
used to determine what current can be drawn from the upstream USB  
port.  
00 = No selected Chargers or Status identified  
01 = 100ma (VBUS detect without enumeration)  
10 = 500ma (Device enumerated, Set Config seen)  
11 = 1000+ma (Charger detected)  
The actual current amount for the charger will be system dependent  