欢迎访问ic37.com |
会员登录 免费注册
发布采购

USB2507_07 参数 Datasheet PDF下载

USB2507_07图片预览
型号: USB2507_07
PDF下载: 下载PDF文件 查看货源
内容描述: 集成USB 2.0兼容7端口集线器 [Integrated USB 2.0 Compatible 7-Port Hub]
分类和应用:
文件页数/大小: 44 页 / 571 K
品牌: SMSC [ SMSC CORPORATION ]
 浏览型号USB2507_07的Datasheet PDF文件第21页浏览型号USB2507_07的Datasheet PDF文件第22页浏览型号USB2507_07的Datasheet PDF文件第23页浏览型号USB2507_07的Datasheet PDF文件第24页浏览型号USB2507_07的Datasheet PDF文件第26页浏览型号USB2507_07的Datasheet PDF文件第27页浏览型号USB2507_07的Datasheet PDF文件第28页浏览型号USB2507_07的Datasheet PDF文件第29页  
Integrated USB 2.0 Compatible 7-Port Hub  
Datasheet  
5.3.1.1  
Byte Protocols  
When using the Hub SMBus Interface for byte transfers, a write will always consist of the SMBus  
Interface Slave Address byte, followed by the Internal Address Register byte, then the data byte.  
The normal read protocol consists of a write to the HUB with the SMBus Interface Address byte,  
followed by the Internal Address Register byte. Then restart the Serial Communication with a Read  
consisting of the SMBus Interface Address byte, followed by the data byte read from the Hub. This  
can be accomplished by using the Read Byte protocol.  
Note: For the following SMBus tables:  
Denotes Master-to-Slave  
Write Byte  
Denotes Slave-to-Master  
The Write Byte protocol is used to write data to the registers. The data will only be written if the protocol  
shown in Table 5.2 is performed correctly. Only one byte is transferred at a time for a Write Byte  
protocol.  
Table 5.2 SMBus Write Byte Protocol  
Field:  
Bits:  
Start  
1
Slave Addr  
7
Wr  
1
Ack  
1
Reg. Addr  
8
Ack  
1
Reg. Data  
8
Ack  
1
Stop  
1
Read Byte  
The Read Byte protocol is used to read data from the registers. The data will only be read if the  
protocol shown in Table 5.3 is performed correctly. Only one byte is transferred at a time for a Read  
Byte protocol.  
Table 5.3 SMBus Read Byte Protocol  
Field:  
Bits:  
Start  
1
Slave  
Addr  
Wr  
1
Ack  
1
Reg.  
Addr  
Ack  
1
Start  
1
Slave  
Addr  
Rd  
1
Ack  
1
Reg.  
Data  
Nack  
1
Stop  
1
7
8
7
8
5.3.2  
Invalid Protocol Response Behavior  
Registers that are accessed with an invalid protocol are not updated. A register is only updated  
following a valid protocol. The only valid protocols are Write Byte and Read Byte, which are described  
above.  
The Hub only responds to the hardware selected Slave Address.  
Attempting to communicate with the Hub over SMBus with an invalid slave address or invalid protocol  
results in no response, and the SMBus Slave Interface returns to the idle state.  
The only valid registers that are accessible by the SMBus slave address are the registers defined in  
the Registers Section. See Section 5.3.3 for the response to undefined registers.  
5.3.3  
General Call Address Response  
The Hub does not respond to a general call address of 0000_000b.  
SMSC USB2507  
Revision 2.3 (08-27-07)  
DATA2S5HEET  
 复制成功!