USB 2.0 Hub and 10/100 Ethernet Controller  
Datasheet  
3.2  
EEPROM Defaults  
The signature value of 0xA5 is stored at address 0. A different signature value indicates to the  
EEPROM controller that no EEPROM or an un-programmed EEPROM is attached to the device. In  
this case, the hardware default values are used, as shown in Table 3.11.  
Table 3.11 EEPROM Defaults  
FIELD  
DEFAULT VALUE  
Ethernet Controller  
MAC Address  
FFFFFFFFFFFFh  
Ethernet Controller  
Full-Speed Polling  
Interval (mS)  
01h  
04h  
Ethernet Controller  
Hi-Speed Polling Interval  
(mS)  
Ethernet Controller  
Configuration Flags  
05h  
01h  
Ethernet Controller  
Maximum Power (mA)  
Ethernet Controller  
Vendor ID  
0424h  
EC00h  
Ethernet Controller  
Product ID  
3.3  
EEPROM Auto-Load  
Certain system level resets (USB reset, POR, nRESET, and SRST) cause the EEPROM contents to  
be loaded into the device. After a reset, the EEPROM controller attempts to read the first byte of data  
from the EEPROM. If the value 0xA5 is read from the first address, then the EEPROM controller will  
assume that the external Serial EEPROM is configured for auto-loading. If a value other than 0xA5 is  
read from the first address, the EEPROM auto-load will not commense.  
Note: The EEPROM contents are loaded for both the Hub and the Ethernet Controller as a result of  
a POR or nRESET. The USB reset results only in the loading of the MAC address from the  
EEPROM. A software reset (SRST) or a EEPROM Reload Command causes the EEPROM  
contents related solely to the Ethernet Controller to be loaded.  