Three Port 10/100 Managed Ethernet Switch with MII  
Datasheet  
7.2.5.1  
PHY Pause Flow Control  
The Port 1 & 2 PHYs are capable of generating and receiving pause flow control frames per the IEEE  
802.3 specification. The PHYs advertised pause flow control abilities are set via bits 10 (Symmetric  
Pause) and 11 (Asymmetric Pause) of the Port x PHY Auto-Negotiation Advertisement Register  
(PHY_AN_ADV_x). This allows the PHY to advertise its flow control abilities and auto-negotiate the  
flow control settings with its link partner. The default values of these bits are determined via  
configuration straps as defined in Section 13.2.2.5, "Port x PHY Auto-Negotiation Advertisement  
Register (PHY_AN_ADV_x)," on page 239.  
The pause flow control settings may also be manually set via the manual flow control registers Port 1  
Manual Flow Control Register (MANUAL_FC_1) and Port 2 Manual Flow Control Register  
(MANUAL_FC_2). These registers allow the switch fabric ports flow control settings to be manually set  
when auto-negotiation is disabled or the Manual Flow Control Select bit 0 is set. The currently enabled  
duplex and flow control settings can also be monitored via these registers. The flow control values in  
the Port x PHY Auto-Negotiation Advertisement Register (PHY_AN_ADV_x) are not affected by the  
values of the manual flow control register. Refer to Section 6.2.3, "Flow Control Enable Logic," on  
page 60 for additional information.  
7.2.5.2  
Parallel Detection  
If the LAN9313/LAN9313i is connected to a device lacking the ability to auto-negotiate (i.e. no FLPs  
are detected), it is able to determine the speed of the link based on either 100M MLT-3 symbols or  
10M Normal Link Pulses. In this case the link is presumed to be half-duplex per the IEEE 802.3  
standard. This ability is known as “Parallel Detection.” This feature ensures interoperability with legacy  
link partners. If a link is formed via parallel detection, then bit 0 in the Port x PHY Auto-Negotiation  
Expansion Register (PHY_AN_EXP_x) is cleared to indicate that the link partner is not capable of auto-  
negotiation. If a fault occurs during parallel detection, bit 4 of the Port x PHY Auto-Negotiation  
Expansion Register (PHY_AN_EXP_x) is set.  
The Port  
x PHY Auto-Negotiation Link Partner Base Page Ability Register  
(PHY_AN_LP_BASE_ABILITY_x) is used to store the Link Partner Ability information, which is coded  
in the received FLPs. If the link partner is not auto-negotiation capable, then this register is updated  
after completion of parallel detection to reflect the speed capability of the link partner.  
7.2.5.3  
Restarting Auto-Negotiation  
Auto-negotiation can be re-started at any time by setting bit 9 of the Port x PHY Basic Control Register  
(PHY_BASIC_CONTROL_x). Auto-negotiation will also re-start if the link is broken at any time. A  
broken link is caused by signal loss. This may occur because of a cable break, or because of an  
interruption in the signal transmitted by the Link Partner. Auto-negotiation resumes in an attempt to  
determine the new link configuration.  
If the management entity re-starts Auto-negotiation by writing to bit 9 of the Port x PHY Basic Control  
Register (PHY_BASIC_CONTROL_x), the LAN9313/LAN9313i will respond by stopping all  
transmission/receiving operations. Once the internal break link time of approximately 1200ms has  
passed in the Auto-negotiation state-machine, the auto-negotiation will re-start. In this case, the link  
partner will have also dropped the link due to lack of a received signal, so it too will resume auto-  
negotiation.  
7.2.5.4  
Disabling Auto-Negotiation  
Auto-negotiation can be disabled by clearing bit 12 of the Port x PHY Basic Control Register  
(PHY_BASIC_CONTROL_x). The PHY will then force its speed of operation to reflect the speed (bit  
13) and duplex (bit 8) of the Port x PHY Basic Control Register (PHY_BASIC_CONTROL_x). The  
speed and duplex bits in the Port x PHY Basic Control Register (PHY_BASIC_CONTROL_x) should  
be ignored when auto-negotiation is enabled.  
Revision 1.2 (04-08-08)  
SMSC LAN9313/LAN9313i  
DATA9S4HEET  
 复制成功!