High Performance Two Port 10/100 Managed Ethernet Switch with 32-Bit Non-PCI CPU Interface  
Datasheet  
11.3  
IEEE 1588 Clock  
The 64-bit IEEE 1588 clock is the time source for all IEEE 1588 related functions of the LAN9312. It  
is readable and writable by the host via the 1588 Clock High-DWORD Register (1588_CLOCK_HI) and  
1588 Clock Low-DWORD Register (1588_CLOCK_LO).  
In order to accurately read this clock, a special procedure must be followed. Since two DWORD reads  
are required to fully read the 64-bit clock, the possibility exists that as the lower 32-bits roll over, a  
wrong intermediate value could be read. To prevent this, a snapshot register technique is used. When  
the 1588_CLOCK_SNAPSHOT bit in the 1588 Command Register (1588_CMD) register is written with  
“1”, the current value of the 1588 clock is saved, allowing it to be properly read.  
When writing a new value to the IEEE 1588 clock, two 32-bit write cycles are required (one for each  
clock register) before the registers are affected. The writes may be in any order. However, caution must  
be observed when changing the clock value in a live environment as it will disrupt linear time. If the  
clock must be adjusted during operation of the 1588 protocol, it is preferred to adjust the Addend value,  
effectively speeding-up or slowing-down the clock until the correct time is achieved.  
The 64-bit IEEE 1588 clock consists of the 32-bit 1588 Clock Addend Register  
(1588_CLOCK_ADDEND) that is added to a 32-bit Accumulator every 100 MHz clock. Upon overflow  
of the Accumulator, the 64- bit IEEE 1588 clock is incremented. The Addend / Accumulator pair form  
a high precision frequency divider which can be used to compensate for the inaccuracy of the  
reference crystal. The nominal frequency of the 64-bit IEEE 1588 clock and the value of the Addend  
are calculated as follows:  
32  
FreqClock = (Addend / 2 ) * 100 MHz  
32  
Addend = (FreqClock * 2 ) / 100 MHz  
Typical values for the Addend are shown in Table 11.4. These values should be adjusted based on the  
accuracy of the IEEE 1588 clock compared to the master clock per the PTP protocol. The adjustment  
precision column of the table shows the percentage change for the specified IEEE 1588 clock  
frequency if the Addend was to be incremented or decremented by 1.  
Table 11.4 Typical IEEE 1588 Clock Addend Values  
IEEE 1588 CLOCK  
(FreqClock)  
1588_CLOCK_ADDEND  
(Addend)  
ADJUSTMENT PRECISION %  
-8  
33 MHz  
50 MHz  
66 MHz  
75 MHz  
90 MHz  
547AE147h  
80000000h  
A8F5C28Fh  
C0000000h  
E6666666h  
7.1*10  
-8  
4.7*10  
-8  
3.5*10  
-8  
3.1*10  
-8  
2.6*10  
SMSC LAN9312  