10/100 Non-PCI Ethernet Single Chip MAC + PHY  
Datasheet  
Regardless of the functional description, all registers can be accessed as doublewords, words or bytes.  
The default bit values upon hard reset are highlighted below each register.  
Table 8.1 Internal I/O Space Mapping  
BANK0  
BANK1  
BANK2  
BANK3  
0
2
TCR  
CONFIG  
MMU COMMAND  
MT0-1  
EPH STATUS  
RCR  
COUNTER  
MIR  
RPCR  
RESERVED  
BANK  
BASE  
IA0-1  
IA2-3  
IA4-5  
PNR  
FIFO PORTS  
POINTER  
DATA  
DATA  
INTERRUPT  
BANK  
MT2-3  
MT4-5  
MT6-7  
4
6
8
A
C
E
MGMT  
REVISION  
ERCV  
GENERAL PURPOSE  
CONTROL  
BANK  
BANK  
A special BANK (BANK7) exists to support the addition of external registers.  
8.4  
Bank Select Register  
OFFSET  
E
NAME  
TYPE  
SYMBOL  
BSR  
BANK SELECT REGISTER  
READ/WRITE  
HIGH  
Reserved  
Reserved  
Reserved  
1
Reserved  
Reserved  
0
Reserved  
Reserved  
Reserved  
BYTE  
0
0
1
0
1
1
LOW  
BS2  
BS1  
BS0  
BYTE  
X
X
X
X
X
0
0
0
BS2, BS1, BS0 Determine the bank presently in use. This register is always accessible and is used  
to select the register bank in use.  
The upper byte always reads as 33h and can be used to help determine the I/O location of the  
LAN91C111.  
The BANK SELECT REGISTER is always accessible regardless of the value of BS0-2  
Note: The bank select register can be accessed as a doubleword at offset 0x0Ch, as a word at offset  
0x0Eh, or as a byte at offset 0x0Eh, A doubleword write to offset 0x0Ch will write the BANK  
SELECT REGISTER but will not write the registers 0x0Ch and 0x0Dh, but will only write to  
register 0x0Eh  
BANK 7 has no internal registers other than the BANK SELECT REGISTER itself. On valid cycles  
where BANK7 is selected (BS0=BS1=BS2=1), and A3=0, nCSOUT is activated to facilitate  
implementation of external registers.  
Note: BANK7 does not exist in LAN91C9x devices. For backward S/W compatibility BANK7 accesses  
should be done if the Revision Control register indicates the device is the LAN91C111.  
Bank 7 is a new register Bank to the SMSC LAN91C111 device. This bank has extended registers that  
allow the extended feature set of the SMSC LAN91C111.  