OPERATIONAL DESCRIPTION
MAXIMUM GUARANTEED RATINGS*
Operating Temperature Range
Storage Temperature Range
0ºC to +70ºC
........................................................................................
-55ºC to +150ºC
......................................................................................
Lead Temperature Range (soldering, 10 seconds)
Positive Voltage on any pin, with respect to Ground
Negative Voltage on any pin, with respect to Ground
+325ºC
...................................................................
VCC + 0.3V
............................................................
...................................................................
-0.3V
+7V
Maximum VCC
...............................................................................................................................
*Stresses above those listed above could cause permanent damage to the device. This is a stress
rating only and functional operation of the device at any other condition above those indicated in the
operation sections of this specification is not implied.
Note: When powering this device from laboratory or system power supplies, it is important that the
Absolute Maximum Ratings not be exceeded or device failure can result. Some power supplies exhibit
voltage spikes on their outputs when the AC power is switched on or off. In addition, voltage
transients on the AC power line may appear on the DC output. If this possibility exists, it is suggested
that a clamp circuit be used.
(TA = 0ºC - 70ºC, VCC = +5.0 V ± 10%)
DC ELECTRICAL CHARACTERISTICS
MIN
TYP
MAX
UNITS
PARAMETER
SYMBOL
COMMENTS
I Type Input Buffer
Low Input Level
VILI
VIHI
0.8
V
V
TTL Levels
High Input Level
2.0
IS Type Input Buffer
Low Input Level
High Input Level
VILIS
VIHIS
VHYS
0.8
0.4
V
V
Schmitt Trigger
Schmitt Trigger
2.2
Schmitt Trigger Hysteresis
250
mV
ICLK Input Buffer
Low Input Level
High Input Level
VILCK
VIHCK
V
V
3.0
69