欢迎访问ic37.com |
会员登录 免费注册
发布采购

FDC37CXFR 参数 Datasheet PDF下载

FDC37CXFR图片预览
型号: FDC37CXFR
PDF下载: 下载PDF文件 查看货源
内容描述: 即插即用兼容超I / O控制器,提供快速IR [Plug and Play Compatible Ultra I/O Controller with Fast IR]
分类和应用: 控制器
文件页数/大小: 258 页 / 898 K
品牌: SMSC [ SMSC CORPORATION ]
 浏览型号FDC37CXFR的Datasheet PDF文件第59页浏览型号FDC37CXFR的Datasheet PDF文件第60页浏览型号FDC37CXFR的Datasheet PDF文件第61页浏览型号FDC37CXFR的Datasheet PDF文件第62页浏览型号FDC37CXFR的Datasheet PDF文件第64页浏览型号FDC37CXFR的Datasheet PDF文件第65页浏览型号FDC37CXFR的Datasheet PDF文件第66页浏览型号FDC37CXFR的Datasheet PDF文件第67页  
During the command phase of the seek or  
recalibrate operation, the FDC is in the BUSY  
state, but during the execution phase it is in the  
NON-BUSY state. At this time, another Seek or  
Recalibrate command may be issued, and in  
this manner, parallel seek operations may be  
done on up to four drives at once.  
c. Read ID command  
d. Read Deleted Data command  
e. Write Data command  
f. Format A Track command  
g. Write Deleted Data command  
h. Verify command  
2. End of Seek, Relative Seek, or Recalibrate  
command  
Note that if implied seek is not enabled, the read  
and write commands should be preceded by:  
3. FDC requires a data transfer during the  
execution phase in the non-DMA mode  
1) Seek command - Step to the proper track  
2) Sense Interrupt Status command  
Terminate the Seek command  
3) Read ID - Verify head is on proper track  
4) Issue Read/Write command.  
-
The Sense Interrupt Status command resets the  
interrupt signal and, via the IC code and SE bit  
of Status Register 0, identifies the cause of the  
interrupt.  
The Seek command does not have a result  
phase. Therefore, it is highly recommended that  
the Sense Interrupt Status command be issued  
after the Seek command to terminate it and to  
provide verification of the head position (PCN).  
The H bit (Head Address) in ST0 will always  
return to a "0". When exiting POWERDOWN  
mode, the FDC clears the PCN value and the  
status information to zero. Prior to issuing the  
POWERDOWN command, it is highly  
recommended that the user service all pending  
interrupts through the Sense Interrupt Status  
command.  
Table 29 - Interrupt Identification  
SE  
IC  
INTERRUPT DUE TO  
0
1
11  
00  
Polling  
Normal termination of Seek  
or Recalibrate command  
Abnormal termination of  
Seek or Recalibrate  
command  
1
01  
The Seek, Relative Seek, and Recalibrate  
commands have no result phase. The Sense  
Interrupt Status command must be issued  
immediately after these commands to terminate  
them and to provide verification of the head  
position (PCN). The H (Head Address) bit in  
ST0 will always return a "0". If a Sense Interrupt  
Status is not issued, the drive will continue to be  
BUSY and may affect the operation of the next  
command.  
Sense Interrupt Status  
An interrupt signal on FINT pin is generated by  
the FDC for one of the following reasons:  
1. Upon entering the Result Phase of:  
a. Read Data command  
b. Read A Track command  
63  
 复制成功!