with a single Relative Seek command is 255  
(D).  
Perpendicular Mode  
The Perpendicular Mode command should be  
issued prior to executing Read/Write/Format  
The internal register, PCN, will overflow as the  
cylinder number crosses track 255 and will  
contain 39 (D). The resulting PCN value is thus  
(RCN + PCN) mod 256. Functionally, the FDC  
starts counting from 0 again as the track  
number goes above 255 (D). It is the user's  
responsibility to compensate FDC functions  
commands that access  
a disk drive with  
perpendicular recording capability. With this  
command, the length of the Gap2 field and VCO  
enable timing can be altered to accommodate  
the unique requirements of these drives. Table  
31 describes the effects of the WGATE and  
GAP bits for the Perpendicular Mode command.  
Upon a reset, the FDC will default to the  
conventional mode (WGATE = 0, GAP = 0).  
(precompensation  
track  
number)  
when  
accessing tracks greater than 255. The FDC  
does not keep track that it is working in an  
"extended track area" (greater than 255). Any  
command issued will use the current PCN value  
except for the Recalibrate command, which only  
looks for the TRACK0 signal. Recalibrate will  
return an error if the head is farther than 79 due  
to its limitation of issuing a maximum of 80 step  
pulses. The user simply needs to issue a  
Selection of the 500 Kbps and  
1 Mbps  
perpendicular modes is independent of the  
actual data rate selected in the Data Rate Select  
Register. The user must ensure that these two  
data rates remain consistent.  
second Recalibrate command.  
The Seek  
The Gap2 and VCO timing requirements for  
perpendicular recording type drives are dictated  
by the design of the read/write head. In the  
design of this head, a pre-erase head precedes  
the normal read/write head by a distance of 200  
micrometers. This works out to about 38 bytes  
at a 1 Mbps recording density. Whenever the  
write head is enabled by the Write Gate signal,  
the pre-erase head is also activated at the same  
time. Thus, when the write head is initially  
turned on, flux transitions recorded on the media  
for the first 38 bytes will not be preconditioned  
with the pre-erase head since it has not yet been  
activated. To accommodate this head activation  
and deactivation time, the Gap2 field is  
expanded to a length of 41 bytes. The format  
field shown on Page 60 illustrates the change in  
the Gap2 field size for the perpendicular format.  
On the read back by the FDC, the controller  
must begin synchronization at the beginning of  
the sync field. For the conventional mode, the  
internal PLL VCO is enabled (VCOEN)  
approximately 24 bytes from the start of the  
Gap2 field. But, when the controller operates in  
the 1 Mbps perpendicular mode (WGATE = 1,  
GAP = 1), VCOEN goes active after 43 bytes to  
command and implied seeks will function  
correctly within the 44 (D) track (299-255) area  
of the "extended track area". It is the user's  
responsibility not to issue a new track position  
that will exceed the maximum track that is  
present in the extended area.  
To return to the standard floppy range (0-255) of  
tracks, a Relative Seek should be issued to  
cross the track 255 boundary.  
A Relative Seek can be used instead of the  
normal Seek, but the host is required to  
calculate the difference between the current  
head location and the new (target) head  
location. This may require the host to issue a  
Read ID command to ensure that the head is  
physically on the track that software assumes it  
to be. Different FDC commands will return  
different cylinder results which may be difficult  
to keep track of with software without the Read  
ID command.  
66  
 复制成功!