Table 25 - Result Phase Table  
FINAL SECTOR  
ID INFORMATION AT RESULT PHASE  
MT  
HEAD  
TRANSFERRED TO  
HOST  
C
H
R
N
0
0
Less than EOT  
Equal to EOT  
Less than EOT  
Equal to EOT  
Less than EOT  
Equal to EOT  
Less than EOT  
Equal to EOT  
NC  
NC  
NC  
NC  
NC  
NC  
LSB  
NC  
LSB  
R + 1  
01  
NC  
NC  
NC  
NC  
NC  
NC  
NC  
NC  
C + 1  
NC  
1
0
1
R + 1  
01  
C + 1  
NC  
1
R + 1  
01  
NC  
NC  
R + 1  
01  
C + 1  
NC: No Change, the same value as the one at the beginning of command execution.  
LSB: Least Significant Bit, the LSB of H is complemented.  
termination), sets the DE bit of Status Register  
to "1", and terminates the Write Data  
Write Data  
1
command.  
After the Write Data command has been issued,  
the FDC loads the head (if it is in the unloaded  
state), waits the specified head load time if  
unloaded (defined in the Specify command),  
and begins reading ID fields. When the sector  
address read from the diskette matches the  
sector address specified in the command, the  
FDC reads the data from the host via the FIFO  
and writes it to the sector's data field.  
The Write Data command operates in much the  
same manner as the Read Data command. The  
following items are the same. Please refer to the  
Read Data Command for details:  
·
·
·
·
·
Transfer Capacity  
EN (End of Cylinder) bit  
ND (No Data) bit  
Head Load, Unload Time Interval  
ID information when the host terminates the  
command  
After writing data into the current sector, the  
FDC computes the CRC value and writes it into  
the CRC field at the end of the sector transfer.  
The Sector Number stored in "R" is incremented  
by one, and the FDC continues writing to the  
next data field. The FDC continues this "Multi-  
Sector Write Operation". Upon receipt of a  
terminal count signal or if a FIFO over/under run  
occurs while a data field is being written, then  
the remainder of the data field is filled with  
zeros. The FDC reads the ID field of each  
sector and checks the CRC bytes. If it detects  
a CRC error in ne of the ID fields, it sets the  
IC code in Status Register 0 to "01" (abnormal  
·
Definition of DTL when N = 0 and when N  
does not = 0  
Write Deleted Data  
This command is almost the same as the Write  
Data command except that a Deleted Data  
Address Mark is written at the beginning of the  
Data Field instead of the normal Data Address  
Mark. This command is typically used to mark  
a bad sector containing an error on the floppy  
disk.  